Research Article

Detecting the Intention to Move Upper Limbs from Electroencephalographic Brain Signals

Table 4

Summary of the classification accuracy, true positive events, and true negative events achieved for all subjects for different window sizes , , and  s.

Classification accuracy
MeanMinMaxTPETNE

0.500.62 ± 0.060.540.680.620.62
0.750.64 ± 0.050.570.700.650.64
1.000.67 ± 0.060.590.720.670.66