Research Article
Sequential Probability Ratio Testing with Power Projective Base Method Improves Decision-Making for BCI
Table 2
Accuracy (%) of different classifiers on the BCI competition datasets.
| Subject | LDA | SLDA | SVM | SSVM | Bayesian | SB |
| S1 | 87.8 | 90.0 | 87.1 | 92.1 | 86.4 | 92.1 | S2 | 74.6 | 88.3 | 74.6 | 85.7 | 76.1 | 90.6 | S3 | 64.4 | 68.2 | 64.4 | 65.4 | 62.2 | 83.1 | S4 | 71.8 | 77.1 | 66.4 | 66.4 | 71.2 | 84.4 | S5 | 64.0 | 64.0 | 60.9 | 63.1 | 61.4 | 66.6 | S6 | 61.2 | 61.2 | 59.1 | 57.1 | 60.4 | 64.1 | S7 | 61.1 | 55.0 | 61.1 | 57.6 | 59.8 | 65.0 | S8 | 95.7 | 98.0 | 87.3 | 96.0 | 97.1 | 98.1 | S9 | 78.2 | 83.6 | 73.7 | 84.2 | 77.9 | 85.9 | S10 | 77.5 | 86.4 | 66.1 | 73.5 | 72.1 | 80.5 | S11 | 78.8 | 80.1 | 76.7 | 83.1 | 78.2 | 79.7 | S12 | 90.4 | 92.4 | 80.5 | 88.4 | 90.8 | 92.8 | S13 | 82.8 | 89.8 | 72.6 | 87.7 | 80.8 | 86.5 |
| Avg. | 76.0 | 79.5 | 71.6 | 76.9 | 75.0 | 82.3 |
|
|