Research Article

Accelerated Computing in Magnetic Resonance Imaging: Real-Time Imaging Using Nonlinear Inverse Reconstruction

Table 6

Autotuning for reconstructing single-slice, dual-slice, and phase-contrast flow MRI acquisitions. for all datasets results in a grid size of .

Single-slice anatomic MRI
Worst configurationBest configuration
FramesThreadsGPUs/threadFpsThreadsGPUs/threadFps

5241.9123.7
10243.0125.0
25114.7227.7
50114.93211.0
200114.93218.1

Dual-slice anatomic MRI
Worst configurationBest configuration
FramesThreadsGPUs/threadFpsThreadsGPUs/threadFps

5243.2215.9
10114.6228.0
25115.04212.3
50115.14218.4
200115.14228.1

Phase-contrast flow MRI
Worst configurationBest configuration
FramesThreadsGPUs/threadFpsThreadsGPUs/threadFps

5241.6212.6
10111.8223.6
25111.9425.8
50111.9427.5
200111.94210.7