Computational and Mathematical Methods in Medicine / 2019 / Article / Tab 3

Research Article

Electrocardiogram Baseline Wander Suppression Based on the Combination of Morphological and Wavelet Transformation Based Filtering

Table 3

Values of the MSE and SNR.

SignalMSESNR

Artificial ECG0.11703.0757
ECG filtered by WT0.01738.9145
ECG filtered by MMF0.005113.5224
ECG filtered by CA0.002416.7154

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.