Research Article
Comparison of Common Methods for Precision Volume Measurement of Hematoma
Table 2
Volumes of hematoma models by voxelization, slice, and 3D-Slicer methods.
| Model | Facets | Segments | Voxel unit | Slice method | Voxelization method | 3D-Slicer method | Method 1 | Method 2 |
| Hematoma 1 (closed) | 13436 | 7 | 0.427 | 6131.83 | 6135.47 | 6135.47 | 6134.42 | Hematoma 1 (unclosed) | 13433 | 7 | 0.427 | 6131.83 | 6135.46 | 6135.46 | 6085.78 | Hematoma 2 (closed) | 2424 | 7 | 0.212 | 1056.25 | 1056.54 | 1056.54 | 1056.18 | Hematoma 2 (unclosed) | 2421 | 7 | 0.212 | 1056.25 | 1056.54 | 1056.54 | 929.30 | Hematoma 3 (closed) | 12582 | 7 | 0.599 | 12104.49 | 12107.78 | 12107.78 | 112107.68 | Hematoma 3 (unclosed) | 12579 | 7 | 0.599 | 12104.48 | 12107.77 | 12107.77 | 11872.43 |
|
|