Research Article

ECG Heartbeat Classification Based on an Improved ResNet-18 Model

Table 6

Sensitivity (Se) and precision (P+) of the improved ResNet-18 model for each AAMI heartbeat class.

AAMI heartbeat classSe (%)P+ (%)

N98.8996.98
V93.8397.44
S76.4583.87
F63.5677.33
Q00