Research Article

Mathematical Modeling of Brain Activity under Specific Auditory Stimulation

Table 2

Data provided by the encephalograph following spectral analysis (for an EEG segment of 20 sec).

Median value for EEG rhythmsIndices for the whole spectrum
DeltaThetaAlpha 1Alpha 2Beta 1Beta 2TotalEdgeAvMedianPeak

P3A12.7662.84.7853.6152.0881.51517.56819.14110.169.5710.16
P4A23.7273.786.6393.8541.5210.78320.30413.6728.7899.1810.16
O1A12.2572.97113.64416.392.5911.89539.74514.45310.359.96110.16
O2A22.4164.02813.1713.791.931.39836.72911.9149.9619.96110.16

Edge (edge frequency): the frequency that establishes, at a value initially set by the operator (90% in our case), the ratio—the left area/the whole area of the spectrum; Av (average frequency): the frequency corresponding to the center of gravity of the spectrum area; median (median frequency): the frequency that divides the area into two equal parts; peak (peak frequency): the maximum energy frequency.