Research Article

Measuring Latency Variations in Evoked Potential Components Using a Simple Autocorrelation Technique

Figure 6

(a) An averaged somatosensory evoked potential (SEP) (average of 30 repetitions) recorded from the scalp (C3-Fz) after stimulation of the right median nerve at the wrist. Recorded from a neurologically normal female. Median values (horizontal lines, right axis) are shown for three time windows which include identified signal components: A (17-23 ms), B (30-40 ms), and C (45-80 ms). (b), (c), and (d) are the autocorrelation histograms for the time windows for A, B, and C, respectively.
(a)
(b)
(c)
(d)