Mechanical Response and Parametric Sensitivity Analyses of a Drainage Pipe under Multiphysical Coupling Conditions
Table 1
Sensitivity analysis of the model mesh size.
Scheme
Scheme 1
Scheme 2
Scheme 3
Component
Soil
Pipe
Gasket
Fluid
Soil
Pipe
Gasket
Fluid
Soil
Pipe
Gasket
Fluid
Number (104)
4.44
3.35
0.12
1.95
4.76
3.52
0.13
2.12
5.02
3.72
0.14
2.33
Test-σmax (MPa)
1.48
FE-σmax (MPa)
1.56
1.60
1.65
T (h)
5.5
7.5
10
Note. Scheme 1 was conducted according to equation (2). The FE-σmax and t were obtained based on the basic parameters mentioned in Section 5.3, without considering groundwater.