Research Article

Mechanical Response and Parametric Sensitivity Analyses of a Drainage Pipe under Multiphysical Coupling Conditions

Table 1

Sensitivity analysis of the model mesh size.

SchemeScheme 1Scheme 2Scheme 3

ComponentSoilPipeGasketFluidSoilPipeGasketFluidSoilPipeGasketFluid
Number (104)4.443.350.121.954.763.520.132.125.023.720.142.33
Test-σmax (MPa)1.48
FE-σmax (MPa)1.561.601.65
T (h)5.57.510

Note. Scheme 1 was conducted according to equation (2). The FE-σmax and t were obtained based on the basic parameters mentioned in Section 5.3, without considering groundwater.