Research Article

A Synchronized Hybrid Brain-Computer Interface System for Simultaneous Detection and Classification of Fusion EEG Signals

Table 2

Comparison of different studies for hybrid MI + SSVEP-based BCI systems.

StudyModelAccuracy (%)CommandsModalityChannelTime windows (s)

Cao et al. [18]290.638Simultaneous152
Ma et al. [19]284.3 & 77.44Simultaneous1611
Allison et al. [20]281.002Simultaneous58
Horki et al. [23]285.004Sequential44
Ko et al. [29]285.602Simultaneous28
Millán [37]287 and 914Sequential58
Long et al. [38]275.405Sequential15N/A
Allison et al. [39]260.008Simultaneous318
Li et al. [40]250–1004Simultaneous152.77–6.76
Our study195.5610Simultaneous25