Research Article
Efficiency-House Optimization to Widen the Operation Range of the Double-Suction Centrifugal Pump
| Level | | | |
| 1 | 84.70 | 88.03 | 86.87 | 2 | 84.14 | 88.69 | 87.51 | 3 | 84.86 | 89.21 | 87.60 | 4 | 83.31 | 88.16 | 87.59 | 5 | 82.25 | 87.41 | 86.45 | 6 | 83.86 | 87.26 | 84.61 | 7 | 83.17 | 87.20 | 86.04 | 8 | 84.58 | 88.43 | 87.25 | 9 | 83.72 | 87.88 | 87.43 | 10 | 83.68 | 87.83 | 86.70 | 11 | 85.07 | 88.44 | 85.61 | 12 | 83.99 | 88.70 | 87.80 | 13 | 84.25 | 88.62 | 88.35 | 14 | 84.87 | 87.68 | 85.07 | 15 | 83.74 | 88.02 | 87.40 | 16 | 85.00 | 88.77 | 86.77 | 17 | 84.96 | 88.66 | 86.28 | 18 | 83.79 | 87.51 | 85.31 | 19 | 83.99 | 87.88 | 85.27 | 20 | 83.92 | 87.85 | 85.66 | 21 | 84.70 | 89.40 | 88.82 | 22 | 84.44 | 88.98 | 86.74 | 23 | 83.29 | 87.83 | 87.37 | 24 | 83.91 | 88.52 | 87.54 | 25 | 83.85 | 88.36 | 86.94 | 26 | 84.17 | 88.90 | 87.88 | 27 | 84.40 | 88.93 | 87.99 | 28 | 83.77 | 87.79 | 85.69 | 29 | 84.15 | 87.87 | 87.72 | 30 | 83.86 | 88.43 | 85.41 | 31 | 84.89 | 88.18 | 87.09 | 32 | 83.01 | 87.17 | 84.72 |
|
|