Research Article

An Extended FMEA Model for Exploring the Potential Failure Modes: A Case Study of a Steam Turbine for a Nuclear Power Plant

Table 5

Top six FMs as well as the inspection and maintenance measures for them.

RankingFMiFailure modeInspection and maintenance measures

1FM9Rotor breakdownMonitor the vibration and temperature of bearings and perform nondestructive inspections on a regular basis to ensure that there is no degradation of the components.
2FM4Fracture of vaneSet standard operating hours and perform regular inspections of turbine vanes.
3FM3Foreign objectsImplement a foreign material exclusion (FME) control system.
4FM2Clogged lubricating oil systemRegular cleaning or replacement of related devices. In addition, the quality of the lubricating oil must be monitored and tested regularly.
5FM6Bearing damageRegular maintenance, inspection, and replacement of bearings with lubricating oil.
6FM8Mechanical transmission breakdownMonitor the speed and vibration of the machinery and perform nondestructive tests on a regular basis.