An Extended FMEA Model for Exploring the Potential Failure Modes: A Case Study of a Steam Turbine for a Nuclear Power Plant
Table 5
Top six FMs as well as the inspection and maintenance measures for them.
Ranking
FMi
Failure mode
Inspection and maintenance measures
1
FM9
Rotor breakdown
Monitor the vibration and temperature of bearings and perform nondestructive inspections on a regular basis to ensure that there is no degradation of the components.
2
FM4
Fracture of vane
Set standard operating hours and perform regular inspections of turbine vanes.
3
FM3
Foreign objects
Implement a foreign material exclusion (FME) control system.
4
FM2
Clogged lubricating oil system
Regular cleaning or replacement of related devices. In addition, the quality of the lubricating oil must be monitored and tested regularly.
5
FM6
Bearing damage
Regular maintenance, inspection, and replacement of bearings with lubricating oil.
6
FM8
Mechanical transmission breakdown
Monitor the speed and vibration of the machinery and perform nondestructive tests on a regular basis.