Abstract

Case. A 13-year-old skeletally immature female presenting with an anterior cruciate ligament (ACL) rupture after a noncontact injury was treated with an intraepiphyseal ACL reconstruction. Flexible instrumentation was utilized to drill a femoral tunnel with an anatomic starting point, with a trajectory that curved inferolaterally away from the physis. At three years postoperatively, she had returned to her preinjury functioning and did not display any lower limb length growth abnormalities. Conclusions. The novel application of curved guides and flexible instruments, with intraoperative fluoroscopy, facilitated growth plate avoidance and a successful outcome of ACL reconstruction in a skeletally immature patient.

1. Introduction

Anterior cruciate ligament (ACL) injuries in children and adolescents have become increasingly common, in part due to increases in youth sports participation [1, 2]. ACL reconstruction in a skeletally immature patient demands special considerations, as violation of open physes during tunnel drilling may produce growth disturbances [35]. Although some studies have shown excellent outcomes and high levels of return to sport after transphyseal ACL reconstruction [4, 6], many authors suggest physeal-sparing methods to avoid causing growth disturbance [2, 3, 58].

The authors of this article hypothesized that it would be possible to create an anatomically placed femoral tunnel that does not violate the physis using a curved guide and intraoperative fluoroscopy. This proposed method would avoid the risk of growth abnormalities with transepiphyseal techniques, while minimizing the risk of nonanatomical tunnel placement previously described in intraepiphyseal reconstruction. The purpose of this report is to describe the case of a pediatric ACL reconstruction using curved instrumentation and intraoperative fluoroscopy to create an anatomically placed femoral tunnel that does not violate the physis. Informed consent and assent were obtained from the patient and her legal guardian for reporting of this case.

2. Case Presentation

A 13-year-old female reported to clinic for evaluation after sustaining a right knee injury five months prior. The patient was 5’2”, 45.3 kg, Tanner Stage 4, and she was 13 years old at age of first menses, and her parents were 5’4” and 5’10”. She reported a hyperextension noncontact injury playing soccer. On exam, she demonstrated full range of motion bilaterally, 2B right Lachman exam, and a right 2+ pivot-shift.

Radiographic imaging was obtained of the right knee demonstrating open physes (Figure 1), and an MRI demonstrated complete tear of her ACL with associated bone contusions. After discussion with this patient and her guardian, it was collectively decided to proceed with arthroscopic ACL reconstruction with a hamstring autograft. The plan was to proceed with an intraepiphyseal ACL femoral fixation technique to minimize the risk for potential growth abnormalities.

3. Treatment and Surgical Technique

The procedure began with autologous hamstring tendon harvests, gracilis, and semitendinosus, which were prepared in a standard quadruple bundle fashion. Each bundle was passed through a 10 mm EndoLoop button (Smith & Nephew, London, England) for fixation purposes. Diagnostic arthroscopy was notable for intact cartilage surfaces of the medial and lateral patellar facets and trochlea. The intercondylar notch was then inspected, and a positive empty wall sign was noted with complete avulsion and marked attenuation of the ACL tissue. The site of the most isometric location for femoral tunnel placement was marked at the intersection of the bifurcate and intercondylar ridges on the inferior one-third of the MWLFC wall. A curved endoscopic guide and Versitomic flexible reaming system (Stryker, Kalamazoo, MI) were used for this technique (Figure 2). The curved guide was advanced through the AM portal and positioned on the marked location. The primary advantage of these instruments is that they allow for recreation of the ACL footprint while optimizing tunnel length and avoiding the need for hyperflexion of the knee [9, 10]. The previous techniques describe placing the curved endoscopic femoral guide in the middle of the femoral footprint at 45° below the horizontal access, resulting in a superolateral trajectory. This trajectory crosses the femoral growth plate and results in an exit point along the anterolateral thigh [9]. In the current technique, the guide was positioned to achieve an inferolateral trajectory (Figures 3 and 4). This was achieved by rotating the guide an additional 85° clockwise from the previously described techniques’ trajectory, so that the guide is 40° above the horizontal plane (Figure 4). With the guide in this position, the knee was placed in 110° of flexion, and a 2.2 mm flexible guide pin was advanced until it exited the femur (Figure 5). The trajectory created by this additional rotation of the guide prevents the guidewire from crossing the physis. Fluoroscopic imaging was used throughout the guidewire advancement to ensure that the physis was not violated. A 4.5 mm drill bit was then utilized to perforate the cortex, creating a tunnel length totaling 35 mm. The tunnel was drilled slowly to prevent possible heat damage to the growth plate [11] [12]. A C-arm was used incrementally during the femoral tunnel drilling as well, to obtain AP (Figure 6) and lateral fluoroscopic views (Figures 5 and 7), confirming appropriate intraepiphyseal positioning of the guidewire without violation of the physis.

The tibial tunnel was then established in standard fashion, exiting on the tibial plateau at the center point of the AM and PL bundles along the anterior intertubercular ridge. The graft was passed across the tibial tunnel, across the notch, and into the femoral tunnel to an appropriate depth, followed by EndoButton flipping for fixation purposes. With the knee in 5° of flexion and a posterior drawer force applied, tension was applied to each of the four tendon strands. A 6 mm dilator followed by a 7 mm GraftBolt PEEK sleeve (Arthrex. Naples, FL) was then advanced to achieve fixation. A 7 mm PEEK interference screw (Arthrex. Naples, FL) was then placed within the sheath to compress the tendon tissue against the walls of the tibial tunnel and to achieve stable purchase. The wounds were then irrigated and closed in standard fashion to complete the procedure.

3.1. Rehabilitation Protocol

After surgery, the patient underwent a standard ACL rehabilitation protocol. Range of motion and weight-bearing was progressed immediately as tolerated. By three months postoperative, the range of motion was from 2 degrees of hyperextension to 140 degrees of flexion, which was symmetric bilaterally. Jogging was initiated at 4 months. Plyometrics and sport-specific rehab was advanced at 5 months postoperatively. At 1-year, she reported that she felt 100% of normal on her operative side. Her physical exam demonstrated a normal gait, and she displayed a symmetric single-leg hop ×5 without pain. She was then released to sport without restriction.

3.2. Final Follow-Up

At a three-year follow-up appointment, she reported a successful return to her baseline function and return to soccer and sport without limitation, further complication or lower limb length growth abnormalities (Figure 8). The side-to-side difference on KT-1000 arthrometer testing was 0.9 mm, in favor of her operative side. She had a grade 1A Lachman exam and a stable pivot-shift exam. Her IKDC, Marx, and Tegner scores at this final follow-up were 95.36, 8, and 9, respectively.

4. Discussion

This case report presents the treatment of an ACL rupture in a skeletally immature pediatric patient with an intraepiphyseal ACL reconstruction utilizing a flexible curved guidewire under intraoperative fluoroscopic guidance, to confirm appropriate femoral tunnel placement. Additional strategies utilized during this procedure to prevent growth plate disturbance included drilling at a slower speed to prevent heat damage to the growth plate and drilling smaller tunnels [12]. A transphyseal technique was used on the tibial side because previous studies have shown excellent outcomes with such combined methods [8, 13], and because most cases of growth abnormalities are attributed to femoral physes violation [14].

Many surgical techniques have been developed to balance the goal of restoring anatomic ACL placement while safely avoiding the physis to prevent growth risks. These physeal-sparing techniques fall into one of two general categories, extra-articular reconstruction [1518], and intraepiphyseal reconstruction [19, 20]. Extra-articular reconstructions are favorable for their ability to prevent any growth-altering structural damage [16]; however, these techniques are neither anatomic nor isometric [21] and they may overconstrain the knee [7]. Several cases of growth disturbances after intraepiphyseal ACL reconstruction in skeletally immature patients have been described, despite the goal of this technique being to avoid this complication [13, 22]. Frosch et al. argue that this might be due to heat damage caused by drilling parallel to the physis, as well as by implant expansion resulting in a pressure effect against the physis [13]. For these reasons, the senior author of this report decided to take a novel surgical approach that would optimize anatomic placement and risk avoidance.

In adults, flexible instrumentation has been shown to create more anatomic and longer femoral tunnels that are further away from the posterior cortex compared to rigid drilling systems [23, 24]. Additionally, these results can all be obtained at lower knee flexion angles with curved instruments, making this stage of the procedure less technically demanding with less risk of complications [9, 10]. Rigid reamers have been shown to create horizontal tunnels with higher tunnel acuity, which may influence contact pressure between the graft and the tunnel aperture [25]. The authors of this report suggest that the benefits of flexible instrumentation may apply in skeletally immature patients, with the added benefit of creating a femoral tunnel that is directed further away from the growth plate. This would theoretically decrease the risk of growth plate disruption directly, along with a decrease in heat damage or pressure effect theoretically observed in tunnels parallel to the growth plate created with rigid instrumentation [13]. However, higher evidence studies are necessary to confirm these hypotheses.

The goals of this all intraepiphyseal ACL reconstruction was to restore functionality and successful return to sport, while avoiding risks of growth abnormalities. The novel application of curved guides and flexible instruments, with intraoperative fluoroscopy, facilitated growth plate avoidance and a successful outcome. This technique is a viable approach to ACL injury in the skeletally immature patient, although higher level studies are needed for further validation of its safety and efficacy.

4.1. Limitations

A notable limitation of this technique presentation is that preoperative KT-1000 and patient-reported outcome measures (including Marx, IKDC, and Tegner scores) were not recorded. For this reason, we were unable to draw conclusions regarding the change in these measures. However, we noted excellent outcomes for both KT-1000 and patient-reported outcome measures for this patient undergoing all inside intraepiphyseal ACL reconstruction with a flexible curved guide. Other limitations of this study include the lack of ability to generalize the findings to the broader population or establishing cause and effect relationships due to the small sample size and retrospective design. Higher-level studies are required to validate the safety and efficacy of the presented technique.

Conflicts of Interest

The authors declare that they have no conflicts of interest.