Research Article

Single-Lung Transplant Results in Position Dependent Changes in Regional Ventilation: An Observational Case Series Using Electrical Impedance Tomography

Table 2

EELI differences between transplanted lung and diseased lung in supine position. Negative results mean a greater reading in the transplanted lung.

VariableMean difference (diseased versus transplanted lung) [in AU]95% confidence interval value

EELI −697−6102, 47070.80
Tidal variation (%)−31−83, 200.23