DPI checklist of the proper inhalation technique and errors.

Correct stepChecklist of inhalation technique errors

Remove or turn coverFailure to open the device
Correctly insert the capsuleFailure to insert the capsule
Pierce the capsuleFailure to pierce the capsule
Load doseIncorrect dose loading
Hold the inhaler uprightKeep the inhaler inclined no more than 45° from the vertical axis during loading
Breathe out the device mouthpieceExhaling into the device mouthpiece after loading
Inhale deeply and quicklyStopping inhaling prematurely
Inhale by mouthInhaling by nose
Forceful and deep inhalationSlow and not forceful inhalation
Breath out the device mouthpieceExhaling into the device mouthpiece after inhalation
Breath-holdNo breath-holding after inhalation