Clinical Study

The Impact of Left Atrial Size in Catheter Ablation of Atrial Fibrillation Using Remote Magnetic Navigation

Table 2

Procedural parameters.

Group A ()Group B ()Total () Value

Procedure duration (min)143.9 ± 31.5139.3 ± 25.1141.6 ± 28.50.295
Duration from mapping begin to ablation finish (min)100.3 ± 30.195.7 ± 25.998.0 ± 28.40.289
Total X-ray time (sec)422.0 (228.0)468.0 (190.0)432.0 (193.5)0.399
Total X-ray dose (gy·cm2)17.1 (11.0)23.9 (19.4)20.9 (18.4)<0.001
X-ray time during mapping and ablation (sec)37.0 (99.0)12.0 (30.1)23.0 (58.0)<0.001
X-ray dose during mapping and ablation (gy·cm2)1.4 (2.7)0.7 (2.1)1.0 (2.2)0.013
Patients using X-ray during mapping and ablation80681480.01
Patients adjust sheath during mapping and ablation472168<0.001
Patients adjust sheath for several times during mapping and ablation132150.007
Times of adjust sheath during mapping and ablation1.0 (1.0)0.0 (1.0)0.0 (1.0)<0.001
Heparin6500.0 ± 1095.46073.2 ± 1331.35960.6 ± 1334.30.283
Complications (minor)000
Complications (major)000
LA volume mapped by C3 (ml)91.8 ± 15.7129.3 ± 35.6109.9 ± 35.2<0.001

C3: Carto 3 system; LA: left atrial. values listed were calculated between Groups A and B.