Research Article

Enhanced Visualization of Retinal Microvasculature via Deep Learning on OCTA Image Quality

Table 4

OCTA parameters of macular area.

MacularSingleMIADenoise value

PSNR344.50<0.0001
Foveal9.220.0035
Superior63.89<0.0001
Nasal25.52<0.0001
Inferior21.80<0.0001
Temporal18.40<0.0001

Notes: repeated-measure ANOVA was used to compare the differences in the PSNR and VD. Abbreviations: OCTA: optical coherence tomography angiography; ANOVA: analysis of variance; PSNR: peak signal-to-noise ratio; MIA: multiple image averaging; VD: vessel density.