Abstract

The process of water infiltration into initially dry sand was studied in horizontal sand columns under various airtight conditions. To investigate the interrelations among water inflow behavior, air pressure, air confinement effect, and vent effectiveness in unsaturated porous media experiencing dynamic infiltration, a total of five dynamic infiltration experiments with fixed inlet water pressure were performed with different air vents open or closed along the column length. Visualizations of the infiltration process were accompanied by measurements of water saturation, air pressure, and accumulated water inflow. In a column system with an open end, the absence of air pressure buildup reveals that the vent at the column end can significantly reduce the internal air pressure effects during infiltration, and the air phase can be ignored for this case. However, in columns with a tight end, the coupled air and water flow processes can be divided into two completely different periods. Before the water front passed by the most distant open vent, the internal air pressure effects on retarding dynamic infiltration are negligible, similar to the open end case. After this period, the open vents can certainly influence the inflow behavior by functioning as air outlets while they cannot equilibrate pore air pressure with the atmospheric pressure. The remaining air ahead of the front will be gradually confined and compressed, and the significant increase in air pressure highlights the great role of air pressure buildup in reducing the water infiltration rate. The closer the last open vent was to the water inlet, the higher was the increase in air pressure and the greater was the delaying effect on water infiltration. This work may extend the experimental study of water infiltration into the unsaturated soils with different airtight conditions and provide experimental evidence on these coupled mechanisms among the water and air phases in soils.

1. Introduction

The influence of air entrapment on water infiltration into unsaturated porous media has been studied for a long time [17]. In cases in which the gas phase displaced by the invading liquid can freely escape from the system, the traditional assumptions that soil air pressure remains constant and in equilibrium with atmospheric pressure are valid [811]. However, in many cases, the movement of air may be impeded by impervious layers or obstructions, leading to a buildup in air pressure and a reduction in the rate of water infiltration due to the entrapped and compressed air phase [2, 1214].

The impact of air confinement on the water infiltration process can be significant for a number of natural conditions [1517]. As reported in Slater and Byers [15], for a fine-grained soil underlain by an impervious rock or clay, the rainfall might seal the surface soil and further resist the air escape. Weeks [16] and Guo et al. [5] showed that heavy rainfall events might produce the Lisse effect in which heavy rainfall produced air confinement and an increase in air pressure that led to a rise of water level in observation wells. Although vertical infiltration in the unsaturated zone is more common and extensively studied, horizontal air-water flow is also expected to occur in many geological circumstances [6, 1820]. For example, the tide-induced air-water flow in coastal areas is a typical two-dimensional air-water flow system. As reported in Jiao and Li [18], a two-phase air-water flow model for predicting the tide-induced variation of air pressure in coastal unsaturated zones under no-rain conditions was developed. They provided a full understanding of the interrelations among the barometric pressure variations, sea tides, and rainfall. In addition, Guo and Jiao [6] numerically investigated subsurface air-water flow subjected to a tidal boundary in a coastal two-layered system. They reported that in such an air-confined system, the vertical air flux tends to be dominant in the upper low-permeability layer and the horizontal air flux is expected to be dominant in the lower relatively high-permeability layer, and both the vertical and horizontal airflow would gradually attenuate landward and upward. More importantly, in volcanic rock reservoir areas, the horizontal fault zones or interlayer staggered zones consisting of mud, debris, and gravel are often formed in river mountains due to tectonic activity [19, 20]. In natural condition, most horizontally developed interlayer staggered zones are initially in the unsaturated state. During reservoir filling, water infiltration into an interlayer staggered zone is also a typical horizontal air-water flow system. As water infiltrates the soil, in regions where the surrounding rock fractures are not developed, the air phase would be expected to be compressed (no airflow boundary), which may contribute a buildup in air pressure and produce a significant effect on retarding the water infiltration process (the horizontal water-air flux tends to be dominant); however, in regions in which some fractures occur in the surrounding rock, a portion of displaced air within the interlayer soils would escape to the surrounding rock mass through these fractures (the vertical water-air flux tends to be dominant). Hence, in unsaturated porous media, experimental investigation of the influence of airflow on horizontal water infiltration in the systems with different airtight conditions is of great importance.

The role of airflow in water infiltration has also been reported in many laboratory tests, and this experimental investigation can be traced to Powers’ experiment which showed that the rate of water entrance into soil columns sealed at the base was less than that when the columns were open to the atmosphere at the base [2]. Free and Palmer [21], Wilson and Luthin [22], Peck [8], and Adrian and Franzini [9] have also studied the delaying effects of air pressure buildup on the water percolation rate in vertical, closed columns packed with homogeneous, initially dry sand. In the work of Wilson and Luthin [22], the air pressure reached a peak value of ~11.0 kPa in unvented columns during infiltration, while the corresponding peak air pressure was ~1.4 kPa for vented columns. Adrian and Franzini [9] noted that a smaller reduction in the infiltration rate in fine-grained soils might be observed in comparison with coarse-grained soils. In some work, stratified columns were also considered. By the use of a vertical stratified unsaturated soil column, Vachaud et al. [23] studied the effects of the air phase on both gravity drainage and constant water infiltration. This delaying effect was measured for both drainage and infiltration. Touma and Vauclin [14] conducted a water infiltration test in vertical, partially saturated columns considering various water boundary conditions applied at the top surface. The results showed that airflow should not be neglected for both flux and ponded conditions. Two types of vertical column were also considered in Latifi et al. [24]: a homogeneous soil column and a two-layered soil column. They showed that air pressure buildup was more significant in the two-layered soil column than in the homogeneous one.

The delaying effect of air pressure on water movement was also observed in some gravity drainage situations if the water drainage rate was higher than the air inflow rate [2529]. Liakopoulos [25] conducted a dynamic drainage experiment in a vertical sand column with an open end; the presence of negative air pressure along the axis indicated that air pressure might have a slightly retarding influence on the drainage behavior. Unlike gravity drainage, more recently, Hou et al. [29] used experimental measurement and numerical modeling to investigate the assumption that air moves without viscous pressure drops (infinitely mobile) in an unsaturated soil column experiencing rapid dynamic drainage. Results of their experiments showed that air pressure gradients within soil could be great and suggested that the assumption of infinite air mobility is a poor assumption in any porous medium experiencing rapid drainage.

Although water vertical infiltration into unsaturated porous media has been extensively investigated, there are few studies that deal with water horizontal infiltration into unsaturated soils at high inlet water pressure. More importantly, the relationship between the airtight condition and the water inflow behavior is unclear. Most of the previous investigators only considered the two extreme cases, including the systems with no air outlets or the systems allowing air to escape freely. No experimental studies have been made in the systems under a range of airtight conditions. Hence, there remains a need for further experimental studies of the interactions among water infiltration, air pressure, vent performance, and air confinement effect during water infiltration into unsaturated porous media.

In this study, a flow visualization system was developed for investigating water horizontal infiltration into unsaturated sand columns. Dynamic infiltration tests were performed under a variety of air confinement conditions with a single or several vents open to allow air to escape from the system at various locations along the column. Water phase movement was tracked with time-domain reflectometry measurements of water saturation at selected locations along the column and with accumulated water inflow. Air pressure at the opposite end of the column was also measured.

2. Horizontal Infiltration Experiments in Unsaturated Sand Columns

2.1. Experimental Setup

Infiltration experiments of water displacing air were performed in horizontal sand columns (Figure 1). The system consisted of a transparent Perspex pipe of 182 cm length, 3.01 cm inside diameter, and 4.62 cm external diameter; a CCD camera (Sony FCB-EX48EP); a water supply system (Wilo, MHIL403); a TDR system to measure soil moisture (range 0-100%, accuracy 3%, resolution 0.1%; HSTL-102STR); and several pressure wireless data loggers (, range 0~98.6 kPa, resolution 25 Pa; Micro-Diver, Schlumberger). Details of this system are shown in Figure 1. All experiments were performed using the sand with grain size ranging from 0.05 to 2 mm. The dry sand was packed into the column to a length of 180 cm by 3.01 cm inner diameter.

The time evolution of water saturation at three positions P1-P3 (, 100, and 170 cm from the inlet) was measured with a time-domain reflectometry system (TDR) by inserting 3.6 cm long probes with a 0.8 cm insulating layer into the sand column. To continuously record the air pressure at the farther end of the column, a pressure wireless monitoring sensor was put in a perfect fit and tightly enclosed stainless steel sleeve (with a minimum dead volume); enabling a sealed connection with the column end. To measure the inlet water pressure, a data logger was placed in the inlet pipe. The air pressure and soil moisture were recorded at 30 s intervals.

The potential influence of air transport on water infiltration under various vented column systems was investigated. To this end, three air vents V1-V3 () were installed in the top side of the horizontal column at different positions (, 120, 60 cm from the inlet) (see Figure 1). When all vents are closed, the sand column is airtight on all boundaries. Various air confinement conditions can be achieved by controlling the vent switching. A total of five scenarios with the same initial condition but different combinations of vents open or closed were performed: (1) Expt. #1 with vent V1 open (the column end) and all other vents closed; (2) Expt. #2 with vent V2 open; (3) Expt. #3 with vent V3 open; (4) Expt. #4 with all vents V1-V3 open; and (5) Expt. #5 with vents V2 and V3 open. Summary of the experimental conditions is presented in Table 1.

2.2. Procedures

Prior to packing, we first have the column vertical. To prevent the sand loss, a 40 μm pore size porous plate with 2 mm thickness was bolted to the column bottom end. The column was filled in ninety layers (2 cm for each layer) to avoid layering or preferential flow, with each layer carefully poured, fully mixed, firmly tapped, and compacted. After packing of the sand, a 2 cm layer of high-permeability gravel (grain size ranges from 5 to 10 mm) was placed at the surface of the sand to promote water infiltration. After that, we bolted a 4 mm pore size porous plate to the column top end to prevent packing loss, and then, the column was turned to a horizontal position.

We connected the right-hand end of the column to the stainless steel sleeve with a built-in air pressure wireless monitoring sensor through a silicone hose, as well as the left end of the column to the inlet pipe with a built-in water pressure wireless monitoring sensor. Note that since there might exist a viscous resistance to water inflow in a pipe, the real inlet water pressure was typically lower than the set value. So a wireless pressure sensor was also placed within the inlet pipe to measure transient inlet water pressure. A hydrophobic Teflon (PTFE) membrane (130 μm thickness, 10 μm pore size; Millipore, LCWP04700) was glued to the one end of the air vent in contact with the soil. The water draining from the vents was collected using a plastic pipe. Furthermore, the pressure data logger was placed in the water supply pipe () as well as each water collecting pipe to calculate inflow or outflow volume (note that the resolution is 0.77 cm3) based on the measurements of hydrostatic pressure. The CCD camera and TDR system were connected to the computer for recording. Before opening the water inlet valve, air within the inlet pipe was fully discharged. We then closed all vents except V1 and regulated the water supply system to a fixed water pressure of 30 kPa. Finally, the water inlet valve was opened, and water dyed with Brilliant Blue FCF (CI 42090) was pumped into the column. It should be noted that in this unsaturated infiltration system, all controlled resistances to flow beyond the baseline system resistances were reduced to a minimum.

When equilibrium was reached (in water-saturated state), a falling-head test was performed to determine the saturated hydraulic conductivity of the packing. In Expts. #2-#5, compared to Expt. #1, only the vents that are open are different, but other procedures remain the same. The porosity and bulk density of the packings were measured by the method provided by Tan [30]. The measured porosity, initial and saturated water content, and bulk density of the packings are, respectively, 0.47, 0.15, 0.43, and 1.67 g/cm3. The temperature of the room in which the dynamic experiments were carried out varied from 17°C to 21°C.

3. Results

As water infiltration proceeds, the air phase in the unsaturated zone is gradually displaced by the invading water, accompanied by an increase in air pressure and water saturation. We characterize general distributions of the saturated, transition, and unchanged zones when the wetting front first reaches (where the saturation begins to increase from the initial water saturation) the selected positions (, , and for points P1-P3; see Figure 1 for their positions). We also analyze the water saturation at points P1-P3, the air pressure at the column end, and the accumulated water volume through the column inlet. Note that the measured air pressure is a relative value based on an atmospheric pressure of 101.3 kPa. The visual observations, as well as these measurements, jointly contribute to the investigation of these coupled air-water flow processes.

3.1. The Unsaturated Water Infiltration

Initially owing to the water pressure gradient near the inlet surface, water began to fill the pore space by displacing and compressing the air phase within the column. Ahead of the water front, a zone approaching the saturated state with some trapped air was continuously evolving and pushing air towards the end of the column. For Expts. #1-#3, as depicted in Figure 2, a deeper blue color indicates a larger degree of water saturation , allowing us to approximately distinguish the three particular zones by color shade, which refer to the saturated zone ( approaches 1), transition zone ( over the initial water saturation but below 1), and unchanged zone ( is equal to the value of initial saturation).

Significant differences between the lengths of the transition zone in different tests can be observed. For each test, as time passed, the transition zone gradually became wider (transition zone at for Expts. #1-#3 is 8, 13, and 21 cm, respectively). Interestingly, by comparison of the resulting transition zone width between Expts. #1-#3, from Figure 2, Expt. #3 yielded the largest transition zone width at each selected time step (2, 14, and 21 cm at , respectively), whereas the lowest width can be measured from Expt. #1 (2, 6, and 8 cm for , respectively). These indicate that the infiltration processes with different vents open are dramatically different. To further analyze and explain these features, the quantitative measurements in Expts. #1-#3 are presented next.

The time-saturation curves of the invading water at points P1-P3 are plotted in Figure 3. As can be seen, there was a gradual increase in water saturation for all points, eventually reaching a peak value approaching 1 at different times. From Figure 3, the times when the wetting front first reached the points are almost identical with those from the visualizations (Figure 2). Compared to Expt. #1, at each point, there was an increase in and (the time taken from wetting to saturation) for all experiments. In particular, comparing Expt. #1 to Expt. #3, there was an increase up to 80% in at point P3 (increased from 13 min for Expt. #1 to 117 min for Expt. #3).

Concerning the distance of the open vent from the inlet , Expt. #1 with V1 open gives the largest of 180 cm (the column end), followed by Expt. #2 with (V2) and Expt. #3 with (V3). Clearly, the results from Figures 2 and 3 strongly suggest that there was a close relation between the value of and the characteristics of the infiltration process. Specifically, the infiltration rate was slowed down after the wetting front reached , and this delaying effect became more pronounced in tests with a smaller , as evidenced by the following: (i) from Figure 2, the transition zone width in Expt. #3 with the smallest of 60 cm was larger than that of the others at any period which indicates that the slowest infiltration rate was measured; (ii) for Expts. #2 and #3 (), we noted a significant increase in transition zone width after the wetting front passed by ; and (iii) for the three experiments, as increased, a rapid drop in followed for all points, showing that the corresponding test had a more rapid infiltration rate; that is, Expt. #1 with the largest of 180 cm produced the highest infiltration rate among the three. By inspecting the variation in air pressure at the farther end of the column (Figure 4), we gain insight into the air movement and further discuss the relationships between the value of , internal air pressure, and inflow behavior.

3.2. The Process of Air Transport

For Expt. 1 with vent V1 open, the air pressure at the column end remained steady at about zero during the whole infiltration process indicating no air pressure buildup at the column end (not shown). However, from Figure 4, in both Expt. #2 and Expt. #3 (), the air pressure increased from the atmospheric pressure to different peaks ; Expt. #2 and Expt. #3, respectively, produced a peak air pressure of 26.03 kPa and 28.01 kPa, smaller than the fixed inlet water pressure of about 30 kPa. It is important to note that for Expt. #2 and Expt. #3, the air pressure did not show an instantaneous increase at the beginning of water infiltration; from the measurements, the initial buildup in air pressure had a lag of 74 min and 16 min for Expt. #2 and Expt. #3, respectively, consistent with the times that the wetting front first reached the open vent , suggesting that the increase in air pressure did not occur until the wetting front passed by the open vent (in fact, the possible air pressure drop within the unsaturated zone could be identified; this behavior will be further presented in Discussion). Evidently, the closer the open vent was to the inlet (smaller ), the higher was the peak value in air pressures and the longer was the time for air pressure to begin increasing .

It is also important to note that for column systems with , once the water passes by the last open vent, the flow of air to this vent would be impeded by the continuous water phase. Assuming that all air is trapped beyond would be unable to escape and would be compressed ahead of the advancing front, one may calculate a theoretical peak air pressure. Comparing these values to the measurements of air pressure indicates that a portion of air beyond must have vented from the system through open vents behind the front (more details are presented in Discussion). Interestingly, as shown in Figure 4, a sudden drop in air pressure for Expts. #2 and #3 at ( for Expt. #2; for Expt. #3) was measured; it is possible that the pressure of the compressed air phase (remained along the top of the horizontal column) would increase to a critical value ( for Expt. #2; for Expt. #3) allowing air to escape through the last open vent. In the period of falling air pressure, the air outflow rate was expected to exceed the water inflow rate. The singularity in air pressure in this period is consistent with visual observations that there was a continuous venting of air from the last open vent after the front had passed the last open vent. After this period, as the rate of imbibition of water exceeded the rate of escape of air, a period of increasing air pressure followed and finally remained at peak value.

In Figure 5, the cumulative water imbibed for Expts. #1-#3 at various times are compared. For all tests, as time increased, a gradual increase in followed and then maintained at different peak values at the end of the test, indicating that the differences in flow behavior between the three experiments could be significant over the duration of imbibition. The experiment with a smaller produced a smaller peak inflow (the total amount of water imbibed), and the peak water imbibed was ~392.04 cm3 and ~366.52 cm3 for the systems with a of 180 cm and 120 cm, respectively, compared with ~319.08 cm3 for the system with a . It is also interesting to note that, as shown in Figure 5, a sudden drop in the inflow rate (the slope of accumulated water imbibed versus time curve) occurred for Expt. #2 and Expt. #3 after a particular time defined here as (note that this behavior was absent in Expt. #1). This abrupt change is likely the result of the wetting front just passing by the open vent at , as the measured was, respectively, 77 min and 18 min for Expt. #2 and Expt. #3, consistent with the time that the wetting front first reached the respective open vent . This result suggests that before , air in pores displaced by the invading water could easily escape from the open vent and there was no air pressure buildup, and as a result, the inflow differences between the three were relatively small. However, after this period, the advancing front has passed by the open vent and the air phase was pushed forward and compressed, leading to a reduced water infiltration rate. This is why extremely different flow behaviors could be observed within the three experiments. The results in Figure 5 evidence, once again, that the horizontal infiltration process in unsaturated sand column is closely tied to the position of the vent which air can escape.

While the above results did report the differences in inflow behavior and internal air pressure between the three experiments with different vents open, only a single vent to discharge air was used, and the performance of the use of multiple vents is not clear. The question remains: Can the use of multiple air vents strongly impact water inflow behavior and internal air pressure? To solve this question, we performed two additional infiltration experiments with three (open V1, V2, and V3 for Expt. #4) or two (open V2 and V3 for Expt. #5) different vents open.

Examination of air pressure variation with time (not shown) in Expt. #4 shows that there was no increase in air pressure over the entire infiltration process, similar to the result of Expt. #1 as expected. Figure 6 shows a replicate of Expt. #2 in Figure 4, but with the addition of a vent V3 at 60 cm from the inlet. One interesting observation is that, despite the differences in the open vents between Expt. #2 and Expt. #5, the time that air pressure started to buildup of the two was approximately the same and equal to about 75 min. In addition, it is also interesting to note that the similarity in air pressure between Expt. #2 and Expt. #5 could also be observed after the onset of air pressure buildup (the differences in the curve of air pressure versus time between the two were small), with differences becoming evident when approaching to peak air pressure ( is equal to 26.03 kPa in Expt. #2, larger than that in Expt. #5 with ). Clearly, the difference in air pressure variation with the time between Expt. #2 and Expt. #5 was relatively small during the whole infiltration processes.

Furthermore, the comparisons of cumulative water imbibed over time between Expt. #1 and Expt. #4, as well as between Expt. #2 and Expt. #5, are both plotted in Figure 7. It is clear from Figure 7(a) that, despite Expt. #4 with the addition of two vents open (V2 and V3) compared to Expt. #1, the difference in water imbibed between Expt. #1 and Expt. #4 was subtle over the course of infiltration. In addition, from Figure 7(b), it is interesting to note that before 75 min (the time period corresponding to the air pressure that remained constant at the atmospheric pressure), the water imbibed curve in Expt. #5 was similar and virtually indistinguishable compared to Expt. #2. After this period, despite an abrupt reduction in the inflow rate observed in both two experiments, the inflow curves failed to converge, with peak inflow of ~366.52 cm3 for Expt. #2, larger than that for Expt. #5 with peak inflow of ~344.58 cm3.

Concerning the open vent farthest from the inlet, its distance from the inlet is defined here as , i.e., 180 cm for Expt. #1 and Expt. #4, 120 cm for Expt. #2 and Expt. #5, and 60 cm for Expt. #3. It is interesting to consider the relationship between the value of and the features of the infiltration process. The results from Figures 6 and 7 indicate that, even though the open vents were different, the very similar wetting processes were observed for column systems with the same , as evidenced by the following: (i) the curves of water inflow and air pressure over time are quite similar between Expt. #1 and Expt. #4 (with the same of 180 cm); (ii) comparing Expt. #2 with Expt. #5, despite the differences in their open vents, the wetting process in Expt. #5 with of 120 cm is, in general, also similar to that in Expt. #2 which has the same . These results indicate that for any specific column system, the location of the last open vent is one of the key factors influencing the characteristics of the infiltration process. The closer the last open was to the inlet, the higher was the peak value in air pressure, contributing to a smaller air confinement effect and a slower wetting process. It is also important to note that for column systems with the same , the use of multiple air vents should also be more effective in reducing air pressure effect.

To describe the hydraulic properties of the packings, we choose the measured water saturation data from Expt. #1 (airflow can be ignored) to determine the two unknowns and in the van Genuchten model, which is widely used to describe the soil-water characteristic curve as follows [31]:

The unsaturated hydraulic conductivity in the VG model is defined as where is the saturated hydraulic conductivity determined by the falling-head tests; is the effective degree of water saturation, ; and are the residual and saturated volumetric water content, respectively; is the reciprocal of the air entry pressure; is a measure of the pore size distribution; and ().

There are four unknowns in the VG empirical model, namely, , , , and . The parameter can be estimated by a higher matrix suction (e.g., 1.5 MPa). The parameters and were fit using the soil moisture characteristic curve. We first assumed the search interval of the unknowns, and the prediction of water saturation at the selected points was obtained by single-phase unsaturated flow modeling (Richards equation). The estimated vector of the soil hydraulic parameter is , and the mathematical model for the inversion of parameters is where the norm value corresponds to the least-squares method which is the most common approach for nonlinear fitting, is the measured water saturation for point at time , is the corresponding numerical prediction, and is the weighted value. The optimization objective function is .

The value of the unknowns was determined using the Levenberg-Marquardt algorithm for least-squares estimation of nonlinear parameters. The measured parameters were and , and the fitted parameters were and .

From the above results, the pore air at a certain point within the unsaturated zone is compressed by the invading water, leading to an increase in air pressure, and then, pore air at this point is gradually displaced by water. When the pores of this point approach the water-saturated state, the transition from a continuum to a discrete state may occur for residual air in pores, as presented in Figure 8. From the classical Young-Laplace theory of capillary hydrostatics, an equilibrium interface between the gas and liquid phases (or between two immiscible fluids) as a result of capillary forces is identified by an equation: where () is the surface tension, is the mean curvature at each point on the interface, and and are the corresponding principal radii of curvature.

When the continuous air in pores becomes discontinuous, if we know the saturation-capillary pressure relationship or the variations in air pressure and water pressure with time, the number of air bubbles per unit volume can be estimated. For instance, in Expt. #1, we assume is the average radius of air bubbles in soil pores, the water saturation of point P3 is at , and the space occupied by the discrete bubbles in a unit volume () is , with a capillary pressure of 513 Pa from the saturation-capillary pressure relationship, where is the sample porosity. The average bubble radius at point P3 is obtained by substituting the capillary pressure into equation (4), i.e., contributing to the mean bubble volume . Accordingly, the number of air bubble per unit volume in Expt. #1 for point P3 at is .

4. Discussion

Many investigators have attempted to use vents to equilibrate soil air with the atmosphere, both in dynamic drainage tests [23, 32, 33] and dynamic infiltration tests [23, 24]. They have reported that the vents can certainly impact the unsaturated flow in porous media by functioning as air inlets or outlets, but in their dynamic experiments, the vents’ effectiveness is still unclear in equilibrating pore air pressure with the atmospheric pressure. It is interesting to consider the rapid drainage experiments conducted by Hou et al. [29]. Hou et al. performed dynamic drainage experiment and modeling in an unsaturated soil column with an additional vent at the middle height of the vertical column with this vent open at the start of the test (note that the vent was connected to the inlet air source, rather than the surrounding atmosphere). In their dynamic drainage experiment, the vent failed to equilibrate pore air pressure with inlet air, and significant internal air pressure drops were observed.

In our dynamic infiltration experiments, from Figures 4 and 6, for all combinations of vents open, before the wetting front passed the farthest open vent (), the absence of air pressure increase suggests that, in this period, the vents in the experiments are able to equilibrate soil air pressure with atmospheric pressure. However, based on the findings presented by Hou et al. [29], it also should be noted that, if saturation of the medium is changing, dynamic flow of fluids would be expected to produce an internal air pressure gradient within the medium, even with a fully functioning vent. Therefore, under dynamic conditions, it is impossible that there is a complete air pressure equilibrium between any vent and pore air. Based on the measured air pressure data, for example, in Expt. #3, before the saturation front passed the farthest open vent (V3), from the above measurements (Figure 4), the difference in air pressure between the column end and the vent V3 is low enough to be ignored (), while this was not true between the vent V3 and the pore air ahead of the front (). At any time of this period, the magnitude of the total pressure drops in the unsaturated portion of the packed column (from the saturation front to the end of the column) can be assessed by the equation:

If the saturation front position and inflow velocity are known at a certain time, by assuming a complete displacement, can be expressed as where is the water pressure at the saturation front, from the VG model is assumed to be approximate to the reciprocal of air entry pressure in the VG model, is the measured water inlet pressure of 29812 Pa, is the infiltration rate, is the length of the water-saturated zone, is the density of water, and is the saturated hydraulic conductivity of the packing.

In Expt. #3 with a single vent at 60 cm from the inlet, from the measured water saturation (Figure 3) and cumulative water imbibed (Figure 5), the inflow rate and the saturated zone length at the time when the front first reached point P1 () are, respectively, and , contributing to . By using the same method, the calculated air pressure drops show that, in all the infiltration experiments, the magnitude of total gas pressure drops within the unsaturated portion of the columns is no more than about 3000 Pa at any time, far less than the inlet water pressure which strongly suggests that before the front reaches the farthest open vent, the internal viscous air pressure drops would not be expected to impact the dynamic infiltration significantly and the open vents work effectively.

Furthermore, it is important to note that equations (6) and (7) are only valid until the front reaches the farthest open vent, since after this period, the measured cumulative water imbibed and visual observations suggest that the air phase was likely to be continuously accumulated at the top of the horizontal column, and there was a continuous venting of air from the last open vent, which has been noted in the preceding section. In addition, from Figures 4 and 6, a gradual increase in the air pressure clearly shows that, while the vents are able to influence the flow behavior by functioning as air outlets, they cannot equilibrate pore air pressure with the surrounding atmosphere once the water front passes the vent.

Measurements of air pressure at the column point can provide a way for measuring the total pressure drop during imbibition. Therefore, a number of additional experiments with an addition of a gas pressure sensor installed at the column midpoint were conducted to measure the gas pressure at the midpoint of the column (please refer to the method of gas pressure measurement provided by Hou et al. [29]); however, all of these efforts failed due to air leak. This is because, compared to the dynamic drainage experiments conducted by Hou et al., all dynamic experiments conducted in this work are horizontal infiltration and focus on the influence of different air boundary conditions on water infiltration, so perfect control of air boundary condition is much more difficult. As reported in Hou et al. [29], they derived an equation for assessing the magnitude of the total pressure drop to the front in the case of vertical drainage. The fact that there was a good agreement between the measured results and the predicted value has proved this equation, which also confirms the validity of equation (7) because the equation for assessing the total pressure drop in the case of horizontal infiltration in this work is derived on the basis of Hou et al.’s work.

Clearly, if the column end is permeable to air, the vents are expected to reduce the internal air pressure effects during infiltration significantly. As a result, the retarding effect from the air pressure buildup is absent for the whole infiltration process and would not be expected to impact the infiltration behavior, which is consistent with the findings of some researchers [2, 22, 24]. However, unlike the open end case, the coupled air and water flow processes in columns with an airtight end can be divided into two completely different periods. Before the wetting front passes by the last open vent, the displaced air will be freely discharged from the open vents, and the internal air pressure effects on retarding the dynamic infiltration are negligible. After this period, presumably, there is some flow of air back to the vent along the top of the horizontal column, but the flow is constrained because of the high water saturation, the remaining air ahead of the front will be gradually compressed and confined, and the great increase in air pressure highlights the significant role of air pressure buildup in delaying water infiltration. Figure 9 illustrates the mechanism responsible for the role of airflow in water horizontal infiltration in an air-confined system.

It is also important to note that, for column systems with an air-permeable end (), from measurements, almost all air can escape from the column at the end of experiments. For , the flow of air to the last vent would be impeded by the continuous water phase once the water passes by this vent. Comparing the values of theoretical peak air pressure to the measurements of air pressure indicates that a portion of air beyond must have escaped from the column system through open vents behind the wetting front. Based on the measurements, we can calculate the amount of air that would be vented and compressed during the entire infiltration process; for example, in Expt. #3, from Figure 5, ~319.1 cm3 of water was imbibed which initially had about 406.6 cm3 of air , where is the total volume of the packings of 1272.3 cm3, is the initial water saturation (0.32), and is the sample porosity (0.47). Hence, if no air flows out after the water passes V3 until , the air in pores would be compressed from about 406.6 cm3 to . This should increase the pressure to absolute. Since the peak air pressure is only about 129.01 kPa absolute from Figure 4, as a molar ratio, the final moles, , to the initial moles of air, , is . So about 73% of the air has been vented (27% of air compressed). The total volume of vented air at atmospheric pressure is . By using the same method as before, the amount of air that has been vented () during Expts. #1, #2, #4, and #5 are, respectively, 96% (392 cm3), 88% (356.2 cm3), 98% (396.5 cm3), and 81% (329.6 cm3). Evidently, Expts. #1 and #4 () yield the largest , followed by Expts. #2 and #5 () and Expt. #3 (), strongly suggesting that the closer the last open vent is to the water inlet (lower ), the larger amount of air in pores will be compressed and entrapped; this is consistent with the air pressure results that a larger peak air pressure is also measured in a closer .

From the above discussion, for , due to the presence of trapped air, the amount of water imbibed would give an average water saturation less than 1.0 at the end of the experiment. However, in Figure 3, the water saturation values go to 1.0 for P1, P2, and P3. Presumably, this is in part due to the last measured point for water saturation only at 170 cm, rather than at the column end (180 cm). More importantly, most of the trapped air might accumulate at the top part of the horizontal column, but the measured probes were inserted into the middle side of the horizontal column. Hence, the probes were used only for measuring the middle part of the samples. In addition, the stainless steel sleeve connected with the column end might have a small amount of storage space for containing trapped air even if it has a minimum dead volume, which might also have a little contribution to this phenomenon.

In general, in a column system with a closed end, it is necessary to be cautious of air confinement effect, which may produce a great influence on delaying dynamic infiltration of water. This air confinement effect is likely to depend on factors such as the vent location, column size, inflow rate, and sand permeability. It also should be noted that for a specific experiment, the vent effectiveness can be significantly different in different periods of infiltration and strongly depends on the development of the water front.

5. Conclusions

We performed five dynamic infiltration experiments in horizontal sand columns considering various airtight conditions by the use of a single or multiple air vents, with a focus on the interactions among internal air pressure, inflow behavior, vent performance, and air entrapment effect. The results of this experimental study suggest that the infiltration behavior in unsaturated porous media with different airtight conditions can be dramatically differently influenced by internal air pressures and this air pressure effect is strongly controlled by the distance to the farthest air vent from which air can escape.

In column systems where the end is open, the air pressure effect would not be expected to influence water inflow behavior because the buildup in pressure is low enough to be ignored during the entire infiltration process. In a column system with a closed end, before the water front passes by the last open vent, the internal air pressure effects on retarding the water infiltration are also negligible; however, after this period, the remaining air ahead of the front will be gradually compressed and confined; the significant rise in air pressure highlights the great role of air compression in delaying water infiltration.

The vent impact on water inflow is strongly dependent on the development of the water front, which can be divided into two periods. Before the front passes the last open vent, the displaced air will be freely discharged from the open vents, and as a result, there is an equilibrium between soil air pressure and atmospheric pressure. After this period, while the vents can still function as air outlets, they fail to equilibrate the pore air with the atmosphere. The air pressure increases from the atmospheric pressure to different peaks. The closer the last open vent is to the water inlet, the larger the amount of air in pores will be entrapped and compressed, producing a larger peak air pressure and a stronger retarding effect on water inflow. In addition, for column systems with the same last open vent, the use of multiple air vents is expected to be more effective in reducing internal air pressure effect.

Some aspects need further investigation, especially concerning the dynamic infiltration or drainage in unsaturated porous media with a low-permeability layer, in which the potential effect of linear or nonlinear deformation of a low-permeability layer on the air-water flow is possible and cannot be excluded.

Data Availability

The experimental data used to support the findings of this study are included within the supplementary information files.

Conflicts of Interest

The authors declare that they have no conflicts of interest.

Acknowledgments

This work was support by the Major Research Plan of the National Natural Science Foundation of China (Project: Groundwater flow in the Yarlung Zanbo River and its evolution, Grant No. 91747204). The authors also gratefully appreciate the funding from China Three Gorges University (Grant No. XLD/2118), the funding from the Fundamental Research Funds for the Central Universities (Grant No. 2017B607X14), and the funding from the China Scholarship Council.

Supplementary Materials

Supplementary file (file name: Experimental data.zip): experimental data including five data files (file name: Fig. 3-7) in .xlsx format, corresponding to the experimental data used in Figures 37 in the manuscript. (Supplementary Materials)