Research Article

Research on Water-Filled Source Identification Technology of Coal Seam Floor Based on Multiple Index Factors

Table 2

Discriminant index of water inrush water source.

Water sample labelWater inflow (m3/h)Water pressure (MPa)Water inrush coefficient (MPa/m)Fault fractal dimensionWater-filled source

W11.42.50.0631.632I
W21.00.80.0711.681I
W343.03.50.3181.539I
W40.50.70.0581.160I
W52.00.60.0501.385I
W60.10.60.0551.765I
W73.00.20.0171.539I
W83.00.40.0331.274I
W920.00.60.0501.274I
W107.00.60.0551.601I
W1130.03.20.1461.539II
W1240.04.30.0511.632II
W1330.02.00.0911.385II
W1435.02.00.0241.632II
W1515.01.20.0551.601II
W1620.02.60.0311.632II
W1745.01.00.0461.385II
W1825.02.60.0311.632II
W1925.01.80.0211.632II
W2040.01.90.0221.632II
W213.01.90.0221.632II