Research Article

Cyclic Loading Test for the Small-Strain Shear Modulus of Saturated Soft Clay and Its Failure Mechanism

Table 2

The test items and accuracy of the dynamic triaxial test system.

No.Test itemsRange valueAccuracy

1Axial displacement100 mmMeasurement resolution reaches 0.08 μm
2Axial stress2 kPaAccuracy can reach 0.1%, that minimum resolution is 0.2 kPa
3Confining stress range3 MPaAccuracy reaches 1 kPa
4Back pressure range2 MPaAccuracy reaches 1 kPa