Research Article

Enhancement of Coal Permeability Using Aqueous NaCl with Microwave Irradiation

Table 6

Change in moisture content in coal rock samples after microwave irradiation (%).

NaCl concentration, (g/L)
Moisture content, (%)
Average reduction rate
Moisture content after microwave irradiationReduction rate of moisture contentMoisture content after microwave irradiationReduction rate of moisture contentMoisture content after microwave irradiationReduction rate of moisture content

1.961.793.853.745.498.564.69
1.952.383.795.135.3710.465.99
1.952.643.795.264.9816.978.29
1.943.053.765.953.9334.4314.48
1.933.373.678.373.5940.1817.31
Average value2.645.6922.12