Research Article
Study on Downhole Throttling Characteristics of High Water Content Gas
Table 1
Structural parameters of well Daji 14-1 and Daji 4-5.
| | Daji 14-1 well | Daji 4-5 well | Gas water ratio (m3/m3) | 800 |
| Artificial bottom hole (m) | 2448.3 | 2472.3 | Tubing wall thickness (mm) | 6.45 | Outer diameter of surface casing (mm) | 244.5 | 244.5 | Formation thermal conductivity (W/(m·K)) | 1.72 | Wall thickness of surface casing (mm) | 8.94 | 8.94 | Thermal conductivity of oil pipe (W/(m·K)) | 50.5 | Outer diameter of gas reservoir casing (mm) | 139.7 | 139.7 | Thermal conductivity of casing (W/(m·K)) | 50.5 | Gas reservoir casing wall thickness (mm) | 9.17 | 9.17 | Thermal conductivity of cement sheath (W/(m·K)) | 0.95 | Gas production (m3/d) | 30715 | 51220 | Annular thermal convection coefficient (W/(m2·K)) | 0.86 | Outer diameter of oil pipe (mm) | 88.9 | 88.9 | Fluid convection heat transfer coefficient (W/(m2·K)) | 0.82 |
|
|