Research Article

Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Biopsy Device for Lymphadenopathy

Table 4

Procedural comparisons between the conventional (Group A) and Franseen (Group B) needle groups.

Group AGroup B value

Number of punctures, median (IQR)3 (3-4)2 (2-4)<0.001
Procedure time (min), median (IQR)27 (20-32)26 (23-29)0.32
Technical success, (%)83/83 (100)71/71 (100)>0.99
Adverse events, (%)0/83 (0)0/71 (0)>0.99