Abstract

Paper Spray Ionization is an atmospheric pressure ionization technique that utilizes an offline electro-osmotic flow to generate ions off a paper medium. This technique can be performed on a Bruker SolariX Fourier transform ion cyclotron resonance mass spectrometer by modifying the existing nanospray source. High-resolution paper spray spectra were obtained for both organic and biological samples to demonstrate the benefit of linking the technique with a high-resolution mass analyzer. Error values in the range 0.23 to 2.14 ppm were obtained for calf lung surfactant extract with broadband mass resolving power (m/ ) above 60,000 utilizing an external calibration standard.

1. Introduction

Since the first practical implementation of electrospray ionization (ESI) with mass spectrometry reported by Yamashita and Fenn in 1984, a number of different atmospheric pressure ionization (API) techniques have been developed [3]. Many API techniques require extensive sample preparation as well as costly consumables to obtain mass spectra. One of the most cost effective and widely available media for chemical separation and analysis is paper. It has been shown that an electro-osmotic flow similar to that of static electrospray can be utilized to interface a triangle of wetted paper to a mass spectrometer (MS); this form of analysis is called paper spray (PS) [49].

The use of a chromatographic medium such as paper allows for the analysis of complex mixtures since separations will occur as the analyte is being driven along the paper medium [7]. Separating analytes on a paper medium provides the benefits of reduced probability of ion suppression and rapid analysis. The paper medium allows for analysis of complex samples such as biological tissue and dried blood spots which are not suitable for traditional infusion techniques due to their complex matrices [4, 7].

One limitation to PS, like many MS techniques that utilize incomplete chromatographic separations is the detector being utilized to perform the analysis. When dealing with complex samples or unknown samples, there is a need for high-quality data in order to determine what is being analyzed. Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers are powerful tools for analysis of complex mixtures due to their unsurpassed capability to obtain broadband high-resolution mass spectra with high mass accuracy. Utilizing PS with a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer as a detector allows for rapid analysis of both unknowns and/or complex mixtures.

In this present work, we show the suitability of a 12 Tesla FT-ICR MS to obtain high-resolution broadband mass spectra utilizing a coffee filter paper spray medium. High-resolution mass spectra were first obtained for polypropylene glycol (PPG) and polyethylene glycol (PEG) standards to test the source. Second, urine and calf lung surfactant extract (CLSE) were analyzed to test the PS source for analysis of complex mixtures not suitable for direct infusion.

2. Materials, Methods, and Instrumentation

2.1. Chemicals

All solvents used were HPLC grade obtained from Sigma Aldrich (St. Louis, MO, USA). PPG was obtained in the form of a tuning standard from Applied Biosystems (Bedford, MA, USA). PEG standard was made by dissolving 1 mg of PEG 2000 obtained from Sigma Aldrich (St. Louis, MO, USA) in 1 mL of HPLC grade water. Coffee filter, Wegmans brand (Rochester, NY, USA), was cut by hand into an isosceles triangle with dimensions of approximately 5 mm (base) by 10 mm (height).

2.2. PPG and PEG

Samples for PPG and PEG PS analysis were prepared by wetting the coffee filter triangle with 10 μL of the standard solutions. The wet filter paper samples were allowed to dry under ambient conditions before PS analysis was performed. Mass spectra were then obtained by wetting the dried paper triangle with 10 μL of 50 : 50 methanol : water and using the method described in Section 2.5.

2.3. CLSE

CLSE was obtained from ONY Inc. (Amherst, NY, USA). Prior to analysis, the sample was stored in chloroform in the refrigerator. Samples for CLSE analysis were produced by wetting a coffee paper triangle with 2 μL of CLSE and allowing the sample to dry under ambient conditions before PS analysis was performed. Mass spectra were then obtained by wetting the paper with 10 μL of 50 : 50 methanol : water using the instrument method described in Section 2.5.

2.4. Urine

Urine samples were collected from two healthy adult males into sterile polypropylene centrifuge tubes (VWR Scientific) and immediately placed in the freezer. The samples were collected in accordance with the Health Sciences Institutional Review Board at the University at Buffalo (HSIRB no. CHE0050411E). Prior to analysis, the samples were thawed to room temperature and 1 mL was pipetted into 2 mL sample vials (Agilent, Santa Clara, CA, USA) for use. Ten μL was injected directly onto a triangular coffee filter and allowed to dry under ambient conditions. Once dry, the filter paper was attached to the mass spectrometer via a copper clip and rewetted using 50 : 50 methanol : water for PS analysis using the instrument method described in Section 2.5.

2.5. Paper Spray FT-ICR Method

High-resolution spectra were obtained on a 12T Bruker SolariX FT-ICR MS (Bruker Daltonics Inc., Billerica, MA, USA) utilizing a modified Bruker nanoelectrospray source. The positive potential was obtained by grounding the paper triangle using a copper clip and applying a negative voltage at the inlet to the mass spectrometer (Figure 1 shows an image of the source). Mass spectra were obtained at various mass to charge ranges with a pre-FT-ICR-trap hexapole accumulation time of 0.400 seconds and an FT-ICR trap accumulation time of 0.025 seconds. All mass spectra were obtained in the positive mode at a spray voltage of 2 kV. Mass resolving power (m/∆m50%) was defined in accordance with the literature [10].

3. Results and Discussion

3.1. Polymer Standards

Polymeric standards were utilized to determine the suitability of PS with high-resolution FT-ICR MS. In FT-ICR MS the resolution of the mass spectra is relative to m/z as well as the number of data points that can be obtained during the detection process. High-resolution spectra require a time domain signal stable for longer than several hundred milliseconds. Polyethylene glycol and polypropylene glycol produce a broad m/z range of ions ideal for testing the suitability of PS with high-resolution mass spectrometry. High-resolution mass spectra of PEG and PPG are displayed in Figures 2 and 3, respectively. Identifies of the oligomer ion detected and their associated errors is given in Tables 1 and 2, respectively.

Signal-to-noise obtained for PEG and PPG after tuning spectra was in excess of 100/1 with absolute intensities that varied shot-to-shot by less than 20%. This allowed ample time for adjustment of the filter paper towards the inlet of the mass spectrometer so as to optimize instrument setup and analysis. Utilizing polymers of known values (provided by the manufacturers; polydispersity not given) such as PEG 2000 and PPG 2000 provides a detection window several hundred m/z wide for broad mass accuracy calibrations for FT-ICR MS.

3.2. Calf Lung Surfactant Extract

Calf lung surfactant extract (CLSE), which is commercially available in drug form as Infasurf, is used to treat respiratory distress syndrome [11]. CLSE is obtained by doing a total lipid extraction on the lavage fluid from a slaughtered calf lung [11, 12]. Phosphatidylcholine (PC) makes 79% of the molar distribution of lipids and consists of a choline head group attached to the phospholipid with varying degrees of unsaturation in the fatty acid chains [2]. Based on the optimized setup determined from previously analyzing the standards, CLSE was then analyzed. PS mass spectra of CLSE are given in Figures 4 and 5, and the identities with associated error provided in Table 3.

3.3. Urine

Due to the complex nature of urine, many small molecules and metabolites were detected at varying intensities using PS with FT-ICR. PS mass spectra, showing numerous lipids and other metabolites obtained from the analyzed urine specimens of two healthy adult male subjects, are shown in Figure 6; an inset of one of these PS mass spectra is shown in Figure 7 while the other is shown in Figure 8. A few of the metabolites identified in the 27-year-old volunteer using the exact mass capability of FT-ICR are provided in Table 4. Metabolites identified in the 44-year-old volunteer using the exact mass capability of FT-ICR are given in Table 5. Of note, the 44-year-old volunteer, who was taking prescribed vitamin D supplements, showed indications of the vitamin D metabolite 25-Hydroxyvitamin D2-25-glucuronide in the urine. Interestingly, both adult male subjects had indications of one or more glucuronides in urine. This may signal a particularly strong propensity for glucuronides to ionize via the PS ionization mechanism; this capability of PS should be further explored.

4. Conclusions

We developed a PS source for Bruker FT-ICR instrumentation that can be utilized for a broad range of chemical species. The PS source was tested on a range of samples and determined the source was suitable for both polymer and biological samples. The PS source provided an API medium for the analysis of complex mixtures while mitigating the possibility of cross contamination due to the disposable nature of coffee filter paper.

Nomenclature

ESI:Electrospray ionization
API:Atmospheric pressure ionization
MS:Mass spectrometer
PS:Paper spray
FT-ICR:Fourier transform ion cyclotron resonance
PPG:Polypropylene glycol
PEG:Polyethylene glycol
CLSE:Calf lung surfactant extract
PC:Phosphatidylcholine
HSIRB:Health Sciences Institutional Review Board.

Acknowledgments

Donation of the CLSE sample from ONY, Inc. and funding from the National Institutes of Health for the 12-tesla FT-ICR (S10RR029517 to T.D.W.) is gratefully acknowledged. This paper is dedicated in remembrance of Dr. Bruce A. Holm.