Abstract

This study evaluated the use of a mixer mill as the homogenization tool for the extraction of free amino acids in meat samples, with the main goal of analyzing a large number of samples in the shortest time and minimizing sample amount and solvent volume. Ground samples (0.2 g) were mixed with 1.5 mL HCl 0.1 M and homogenized in the mixer mill. The final biphasic system was separated by centrifugation. The supernatant was deproteinized, derivatized and analyzed by gas chromatography. This procedure showed a high extracting ability, especially in samples with high free amino acid content (recovery = 88.73–104.94%). It also showed a low limit of detection and quantification (3.8 · 10−4–6.6 · 10−4μg μL−1 and 1.3 · 10−3–2.2 · 10−2μg μL−1, resp.) for most amino acids, an adequate precision (2.15–20.15% for run-to-run), and a linear response for all amino acids (R2 = 0.741–0.998) in the range of 1–100 µg mL−1. Moreover, it takes less time and requires lower amount of sample and solvent than conventional techniques. Thus, this is a cost and time efficient tool for homogenizing in the extraction procedure of free amino acids from meat samples, being an adequate option for routine analysis.

1. Introduction

Meat and meat products are a good source of amino acids and their proteins are considered of high biological quality. After consumption of meat, free amino acids are rapidly absorbed, while proteins are easily hydrolysed into peptides and amino acids, which in turn are also absorbed. Apart from their nutritional importance, amino acids also influence meat palatability [1] and flavour [2], through the generation of volatile compounds by Maillard reactions and Strecker degradations [36]. During the processing of dry-cured meat products, such as dry-cured ham or loin, there happens an increase in free amino acid content as a consequence of proteolytic activity [4, 7]; indeed, the amount of most amino acids increases with processing time and with higher processing temperatures [3, 8, 9]. Glutamic acid and phenylalanine have been found to be the major amino acids in fresh meat, while in dry-cured products glutamic acid, arginine, and lysine have shown the highest levels [10].

Traditionally, the most common method to analyze free amino acids in food matrices has been reverse phase-high performance liquid chromatography (RP-HPLC) with a precolumn derivatization step [10]. Gas chromatography coupled with mass spectrometry (GC-MS) can be also used as an alternative method, especially when sample amounts are limited and high sensitivity is required [11]. In addition GC presents higher resolution and speed of analysis and lower instrumental cost than HPLC [12]. When GC was first used for the analysis of amino acids, its main drawback was the time consuming and tedious derivatization steps (esterification + acylation) required. Then, the simultaneous silylation of the amino and carboxyl groups in a single step, first using bis(trimethylsilyl)trifluoroacetamide (BSTFA) [13] and later with N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) [14], was developed. MTBSTFA allows the use of milder derivatization conditions [15]. Jiménez-Martín et al. [10] have demonstrated the suitability of using MTBSTFA for the determination of free amino acids in different animal source foods.

A previous free amino acid extraction is required before their derivatization and further analysis. Most extraction methods for amino acids in food products involve using perchloric acid or hydrochloric acid (HCl) diluted in water or in ethanol [9, 10, 12, 1620]. Other solvents for the extraction of amino acids have also been described in the scientific literature, such as ethanol [21], and solvent mixtures, such as water/acetonitrile (50 : 50, v/v) [22] or 0.1% (v/v) formic acid in 20% (v/v) methanol [23]. After mixing the sample with the solvent, the homogenization step is essential for the amino acids to be extracted. For this purpose, different techniques have been used, that is, stirring [12], ultraturrax [16, 17], stomacher [10, 17], omni mixer [9], rotary mixer at 50°C [21], vortex [23], and a heating block at 40°C with stirring [18]. Then, centrifugation is usually carried out, followed by the collection of the supernatant [20] and its filtration through glass wool [9, 10], nylon membrane [23], or Whatman 42 paper [17]. Some authors clean up the supernatant through a cartridge [12, 21] and others do not specify the filtration procedure [9, 20].

The search for new and accurate methods for amino acid analysis in meat and meat products is challenging. The development of derivatization and chromatographic procedures has been thoroughly studied, while less attention has been paid to the extraction methods [24]. Recently, Jiménez-Martín et al. [10] described a GC-MS method for the determination of free amino acids in animal source food. In this methodology, the sample is homogenized with HCl 0.1 M by using a stomacher. Acetonitrile is used for deproteinizing and MTBSTFA for derivatizing. The application of this GC-MS method for the determination of amino acids in meat and meat products constitutes an important reduction in time and solvents in the separation and detection procedures in comparison to RP-HPLC with diode array detector method [3, 4, 8, 9]. However the extraction protocol is time consuming and requires a large amount of sample and solvent, which makes it frequently not suitable for routine analysis.

The present work is focused on the homogenization step for the amino acid extraction from meat samples, with the main goal of reducing sample amount, solvent volume, and extraction time. Recently, Segura and Lopez-Bote [25] developed a new procedure to extract intramuscular fat from pork based on homogenizing the samples using a mixer mill, which allowed minimizing the sample amount, the solvent use, and the analysis time, which are important advantages for routine analysis. The mixer mill is a compact versatile bench-top unit, which has been developed specially for homogenizing small amounts of sample quickly and efficiently by impact and friction. The grinding jars perform radial oscillations in a horizontal position. The inertia of the grinding balls causes them to impact with high energy on the sample material at the rounded ends of the grinding jars and pulverizes it. Also, the movement of the grinding jars combined with the movement of the balls results in the intensive mixing of the sample. The degree of mixing can be increased even further by using several smaller balls.

Thus, the objective of this study was to evaluate the use of the mixer mill as homogenization tool in the extraction of free amino acids from meat samples, in order to analyze a large number of samples in the shortest time, minimizing sample amount and solvent volume.

2. Material and Methods

2.1. Samples

This study was developed with two different meat samples, fresh pork loin and dry-cured ham. These samples were obtained from a local store. First, samples were ground using a commercial grinder. Subsequently, the moisture content of the products was determined according to the method of the Association of Official Analytical Chemists [26] (moisture reference 935.29). The rest of the ground samples were stored at −80°C until free amino acid analysis.

2.2. Reagents

Hydrochloric acid (HCl), 37% extra pure, was used for the amino acid extraction (Scharlau, Barcelona, Spain). Acetonitrile of HPLC-gradient grade (Panreac, Barcelona, Spain) and dichloromethane (Merck, Darmstadt, Germany) were used for the amino acid deproteinization and derivatization procedures. MTBSTFA (Sigma-Aldrich, Madrid, Spain) was the derivatization reagent. Standard amino acids (Sigma-Aldrich) purchased for preparing the standard solutions were alanine, glycine, valine, leucine, isoleucine, proline, methionine, serine, threonine, phenylalanine, aspartic acid, hydroxyproline, cysteine, glutamic acid, arginine, asparagine, lysine, glutamine, histidine, tyrosine, tryptophan, and cystine. DL-Norleucine (Sigma-Aldrich) was used as internal standard (IS).

2.3. Amino Acid Extraction Methods

Two methods for the amino acid extraction were compared. They mainly differ in the homogenization procedure, carried out with stomacher () or mixer mill (). Both methods used HCl 0.1 M as solvent extraction and the sample : solvent ratio was 1 : 7.5. The free amino acid content of fresh loin () and dry-cured ham () was analysed by using the two extraction methods. Each sample was analysed in triplicate.

2.3.1. Stomacher Method

Samples (2 g) were weighed, mixed with HCl 0.1 M (15 mL), and subsequently homogenized in a stomacher (Stomacher 400, Lab-Blender, Barcelona, Spain) for 4 min, as described by Jiménez-Martín et al. [10]. From the stomacher bag, 2 mL was transferred to a safe-lock micro test tube and centrifuged (10000 rpm) (Eppendorf Centrifuges, model 5810R) for 15 minutes at 4°C. The supernatant was stored at −80°C until analysis.

2.3.2. Mixer Mill Method

Ground samples (0.2 g) were homogenized with HCl 0.1 M (1.5 mL) and three stainless steel balls (2 mm of diameter) in the mixer mill (MM400, Retsch technology, Haan, Germany) during 2 min and centrifuged (10000 rpm, 15 min, 4°C). After then, the supernatant was stored at −80°C until analysis.

2.4. Deproteinization and Derivatization

To deproteinize the sample, 250 μL of acetonitrile was mixed with 100 μL of the extract in safe-lock micro test tube and centrifuged at 10000 rpm for 3 min. 100 μL of the supernatant was transferred to heat-resistant tubes and 100 μL of IS solution (5 μg mL−1) was added. Then, tubes were dried under nitrogen. The residual water was removed adding 50 µL of dichloromethane to the dried samples and again evaporated under nitrogen. Finally, 50 μL of MTBSTFA and 50 μL of acetonitrile were added to the dried tubes, which were shaken and subsequently incubated at 100°C for 60 min to induce the derivatization reaction to occur. Then, tubes where stored at refrigeration and analyzed by GC-MS within the next 24 hours.

2.5. Instrumentation

The chromatographic analysis was carried out in a GC equipment 5890 series II (Hewlett-Packard, Barcelona, Spain) coupled to a mass selective detector (MSD) electron impact (EI), model 5973 (Agilent, Barcelona, Spain). A 1 μL portion of the derivatized extract was injected in splitless mode onto the column. The column used was a 50 m × 0.32 mm i.d., 1.05 μm, HP-5 (Hewlett-Packard), being a 5% phenyl-methyl polysiloxane bonded phase fused silica capillary column. Column head pressure was 12.8 psi, resulting in a flow of 1.2 mL/min at 280°C. The oven program was as follows: 170°C for 5 min, 4°C/min ramp to 200°C, held at 200°C for 3 min, 4°C/min ramp to 290°C, held at 290°C for 1 min, 20°C/min ramp to a final temperature of 325°C, and held for 15 min. The transfer line to the mass spectrometer program was as follows: 280°C for 35 min, 10°C/min ramp to 320°C. Total run time was 55.75 min. Free amino acids were identified both by their retention time and by comparison of their characteristic m/z ions with those published in the literature [9, 10]. The quantification was carried out in the selected ion monitoring (SIM) mode. Table 1 shows retention time (Rt), ions selected in SIM mode, and the selected ion for quantification of each amino acid in this study. A calibration curve (quantification ion AA peak area/quantification ion IS peak area versus AA amount/IS amount) was constructed, obtaining values of 0.9999. The final results, expressed in microgram per 100 gram sample dry weight, take into account the moisture content and the exact weight of the sample.

2.6. Standard and Calibration Curves

A standard calibration solution containing 200 µg mL−1 for each AA was prepared (0.5 g of each amino acid was dissolved in 250 mL of HCl 0.1 M). From this solution, seven decreasing dilutions were made (150, 100, 50, 25, 10, 5, and 1 μg mL−1). A stock solution of IS at 5 μg mL−1 was prepared in 0.1 M HCl.

2.7. Quality Control

Quality control of the GC-MS analysis was performed through the routine analysis of procedural blanks and quality control standards and samples to ensure the absence of contaminants and the possible carryover between samples and to assess the quality of the results. Limit of detection (LOD) and quantification (LOQ) based on a signal/noise ratio of 3 : 1 and 10 : 1, respectively, were determined using aqueous standard solutions () with the following equations: LOD = 3SD/ and LOQ = 10SD/, where, for each free amino acid, SD is the standard deviation of the average of the signal obtained for the calibration solution of lowest concentration (0.1 mg/100 mL) and is the slope of the analytical curve calculated with the calibration solutions. For calculating the relative standard deviation (RSD) run-to-run, five replicate analyses of samples were done. In these determinations, ions were selected in SIM mode.

In order to study the recovery for each AA, loin and dry-cured ham samples were spiked with appropriate amounts of AA (7.5–40 μg) each and were extracted using and methods. Moreover, the recovery was also calculated in unspiked samples, using the aqueous standard solutions.

2.8. Statistical Analysis

The effect of the extraction method on total chromatographic area as well as on the content of each detected amino acid was analysed by the Student’s t-test for independent samples. Linear regression analysis was carried out in order to compare the response of the different homogenization tools. The SPSS package (v 18.0) was used.

3. Results and Discussion

3.1. Evaluation of the Mixer Mill as Homogenization Tool for Free Amino Acid Extraction

The chromatographic areas of each free amino acid detected in fresh loin and dry-cured ham samples homogenized by using and are shown in Figure 1. Most AA showed no statistical differences in fresh loin between and , whereas in dry-cured hams chromatographic areas of free amino acids were significantly higher () when using than for extraction.

Figure 2 shows a GC-MS chromatogram of the free amino acids detected in fresh loin (Figure 2(a)) and dry-cured ham (Figure 2(b)) when using . Twenty-one free amino acids were detected in dry-cured samples: alanine, glycine, valine, leucine, isoleucine, proline, methionine, serine, threonine, phenylalanine, aspartic acid, hydroxyproline, cysteine, glutamic acid, asparagine, lysine, glutamine, arginine, histidine, tyrosine, and tryptophan, while fresh loin samples presented 18 free amino acids, the same as dry-cured hams except for arginine, histidine, and tryptophan.

Results on free amino acid content in fresh and dry-cured hams using and homogenization tools are shown in Table 2. As expected, most amino acids showed a higher content in dry-cured ham than in fresh loin, which is in agreement with previous results [10]. This can be ascribed to the longer time during which the proteolytic activity takes place in the processing of the hams [4, 8, 9].

Content of most amino acids from fresh loin did not show statistical differences between and , and nor did the sum of total amino acids. However, hydroxyproline and glutamic acid were only detected when using . In addition, the profile of free amino acid did not vary with the homogenization method. Major free amino acids in loins were glutamine (148.33 and 153.93 mg/100 g sample dry matter in and , resp.), cysteine (100.99 and 103.71 mg per 100 g sample dry matter in and , resp.), while leucine (12.22 and 11.77 mg per 100 g simple dry matter in and , resp.), isoleucine (11.30 and 10.75 mg per 100 g simple dry matter in and , resp.), hydroxyproline (nondetected and 10.24 mg per 100 g simple dry matter in and , resp.), and valine (11.20 and 8.80 mg per 100 g simple dry matter in and , resp.) showed the lowest content. The levels of the other amino acids detected in fresh loin were between 29 and 69 mg per 100 g sample dry matter. These results are in agreement with previous findings. Glutamine has been described as the major amino acid in fresh meat [27, 28]. In relation to the tryptophan, it has been detected in low concentration in fresh meat [29]. According to results found by Jiménez-Martín et al. [10], glutamic acid is the major amino acid in fresh pork, followed by glutamine, cysteine, and phenylalanine.

In dry-cured ham samples, most amino acids detected and the sum of total amino acids showed higher content when using for extraction as compared to . The procedure could break more effectively the meat gel structure formed during the processing of the dry-cured hams than the one. In fact, other authors [29, 30] observed a difficulty of protein extraction during the processing of Iberian hams, even using solutions with high ionic strength for their extraction. The observed suitability of the in the extraction procedures for the analyses of these compounds could be related to the combined movement of the grinding jars with the balls, which results in an intensive mixing of the ham sample with the solvent.

The obtained results highlight the accuracy of the homogenization tool, which is crucial in the case of samples containing high amino acid content, as dry-cured hams do. This is in concordance with results found by Segura and Lopez-Bote [25], who tested the mixer mill for the extraction of intramuscular fat. These authors noticed that the higher extracting ability of the mixer mill was more evident in samples with high levels of intramuscular fat rather than in low lipid content ones.

In spite of the influence of the homogenization tool on the free amino acid content in dry-cured hams, the overall profile of amino acids was similar with and extraction methods. Glutamic acid (352.89 and 520.02 mg per 100 g sample dry matter in and , resp.) and lysine (356.36 and 554.91 mg per 100 g sample dry matter in and , resp.) were the major amino acids in dry-cured ham samples, with hydroxyproline (14.45 and 20.48 mg per 100 g sample dry in and , matter, resp.) and asparagine (47.83 and 37.09 mg per 100 g sample dry in and , matter, resp.) being the minor ones. The content of the other amino acids in dry-cured ham was between 54 and 307 mg per 100 g sample dry matter. Previous research on dry-cured ham showed similar results [4, 810]. Nevertheless, considering results from different works, it can be noticed a high variability in the content of some amino acids from hams; that is, Jurado et al. [7] found higher content of glutamic acid (1269 mg per 100 g sample dry matter) than Martín et al. [4] (650 mg per 100 g sample dry matter), Pérez-Palacios et al. [9] (271 mg per 100 g sample dry matter), and Jiménez-Martín et al. [10] (271 mg per 100 g sample dry matter). These differences may be ascribed to the different processing of hams (salting time, temperature, and moisture conditions). Moreover, several factors may affect aminopeptidase activity during dry-cured ham processing, such as sodium chloride, which is a potent inhibitor for these enzymes [31]. In addition, the water loss and the subsequent reduction in water activity that takes place during dry-cured ham processing also influence the proteolytic activity [32]. Free amino acid accumulation has a feedback effect, reducing aminopeptidase activity [33]. Finally, the variability in the content of free amino acids among works can be also related to the differences in the extraction method. In fact, this work shows significant differences in the content of amino acids of the same samples analyzed under the same conditions, except for the procedure of the extraction method.

Correlation analysis between amino acid content obtained using the and extraction methods was carried out in order to compare the response of two methodologies. Table 3 shows regression equations and coefficient of determination for each amino acid detected. It can be observed that the response is linear for all amino acids ( = 0.741–0.998), suggesting that the validity of the homogenization tool is similar to that of one, which has been previously validated [10].

Amount of sample and volume of solvent used and time consumed are notable aspects to take into account when comparing methodologies. At this respect, time analysis, sample quantity, and solvent volume for the extraction of free amino acids in twenty samples by using and homogenization tools were estimated (Table 4). takes less time and requires lower amount of sample and solvent than (2 versus 80 min, 4 versus 40 g, and 30 versus 300 mL, resp.).

The observed ability of the method in the homogenization process for extraction of free amino acids in meat samples, reducing notably sample and solvent amount as well as time consuming, makes it appropriate for routine analysis.

3.2. Quality Control

The performance of the GC-MS method was examined by determining quality parameters for each individual amino acid. Good linearity was obtained for the range 1–100 μg mL−1 for the 22 standard amino acids. The correlation coefficients were >0.90, except for tryptophan ( = 0.837). Most amino acids showed a poor linearity above 150 μg mL−1; thus, curve point at this concentration or higher was avoided. A similar behaviour was reported previously [10]. LOD and LOQ of the analytical procedure ranged from 3.810−4–6.610−4μg μL−1 to 1.310−3–2.210−2μg μL−1, respectively, for alanine, glycine, valine, leucine, isoleucine, proline, methionine, serine, threonine, phenylalanine, aspartic acid, histidine, and tyrosine. For glutamine, asparagine, lysine, glutamic acid, tryptophan, and cysteine these values were around 0.02–0.2 µg µL−1 and 0.07–0.66 µg µL−1 for LOD and LOQ, respectively. These results are quite in concordance with previous studies [10, 24]. Hydroxyproline and cysteine had higher values for LOD (0.38 and 1.27 µg µL−1, resp.) and LOQ (0.98 and 2.98 µg µL−1, resp.). In fact, previous studies using RP-HPLC-DAD for analyzing amino acids from dry-cured hams did not allow the detection of hydroxyproline and cysteine [8]. Adequate precision was achieved with a RSD of 2.15–20.15% for run-to-run.

Table 5 shows the recovery of AA in aqueous standard solution and in spiked samples (loin and dry-cured ham) extracted by using both and extraction methods. In aqueous standard solution all AA showed high recoveries (94.49–105.75%), indicating the accuracy of the chromatographic procedure. In the samples, most AA showed higher recoveries when using the method for the extraction in comparison to the one, especially in dry-cured ham. This result points out the suitability of the mixer mill for the extraction of AA and it is in concordance with other studies in AA from meat samples [34].

4. Conclusions

The mixer mill is an appropriate tool for the homogenization step in the extraction procedure of free amino acids from meat samples, especially in samples with high free amino acids content. In addition, this technique notably reduces sample amount and solvent volume as well as analysis time. Thus, it could be an adequate option for routine analysis of free AA in meat and meat products.

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.

Acknowledgments

This study was supported by the CONSOLIDER-Ingenio 2010 project (CARNISENUSA, ComisiónInterministerial de Ciencia y Tecnología) and by the Gobierno de Extremadura (GR10180).