Research Article

Innovative Monitoring of Atmospheric Gaseous Hydrogen Fluoride

Table 3

HF concentration (mg/m3) measured in an Italian company during the superbrightening of aluminium surfaces of downlight reflectors (sampling time: 15 min).

Working operationMini sampler Cassette
Fluoride HFFluoride HF

Plant on<0.030 0.035<0.030 0.029
After dipping n. 1 downlight reflector <0.030 0.063<0.030 0.066
After dipping n. 10 downlight reflector 0.048 0.3760.059 0.401
After dipping n. 20 downlight reflector 0.059 0.4790.061 0.486
Plant off<0.030 0.043<0.030 0.049