Research Article

Development of a New Sequential Extraction Procedure of Nickel Species on Workplace Airborne Particulate Matter: Assessing the Occupational Exposure to Carcinogenic Metal Species

Table 6

Determination of Ni’s fraction in powders (μg/g) and environmental samples (μg/m3) collected in the departments of the steel production facility.

Powder (g/g)NiSO4Ni3S2Ni(0)NiOΣNi Tot AAS

A (1.2 mg) //145196341423

B (1.1 mg)272739574566731054011509

C (0.1mg) //323356679695

D (1.0 mg)5802322180444074327538

Filters (g/m3)NiSO4Ni3S2Ni(0)NiOΣNi Tot AAS

Filter A0.320.070.641.52.532.81

Filter B0.250.670.941.02.863.12

Filter C0.760.281.63.56.146.44

Filter D0.870.734.05.010.610.88

Filter E0.890.240.551.32.983.50