Research Article

Application of Multivariate Statistical Analysis to Simultaneous Spectrophotometric Enzymatic Determination of Glucose and Cholesterol in Serum Samples

Table 3

Optimized parameters and errors obtained by ANNs.

ā€‰GlucoseCholesterol

Architecture41-6-141-10-1
Number of iterations2024
Hidden layer transfer functionTansigTansig
RMSETr1 (mg/dL)0.02410.0720
RMSEM1 (mg/dL)0.12210.1130
RMSET1 (mg/dL)0.07300.3809
RMSE, P2 (mg/dL)0.38650.5104
REP2 (%)9.6612.76

They are the RMSE for training, monitoring, and testing for the calibration set, respectively.
2Errors obtained between nominal and estimated concentrations by ANNs for the calibration set.