Research Article
Data Analysis and Results of the Radiation-Tolerant Collaborative Computer On-Board OPTOS CubeSat
Table 1
CoolRunner-II proton irradiation results. Weibull fitting parameters.
| DUT | W | S | ETh (MeV) | Saturation cross section (cm-2 device-1) |
| 1 (SEU-SRAM) | 5.4 | 0.58 | 10.8 | 2.13·10-8 | 4 (SEFI) | 4.0 | 0.46 | 10.8 | 5.70·10-9 | 5 (SEFI) | 4.1 | 0.53 | 10.8 | 6.61·10-9 | 7 (SEU-SRAM) | 5.6 | 0.65 | 10.8 | 2.35·10-8 |
|
|