Abstract

A mode-stirred reverberation chamber (RC) is nowadays a commonly accepted performing tool for over-the-air (OTA) communication system evaluation, and their standardization is underway. Before performing active measurements of wireless communication systems using an RC, field uniformity inside the RC working volume has to be measured following the calibration method described in IEC standards 61000-4-21 and 61000-4-3, which requires 24 calibration measurements of field amplitude. In this contribution, we present the statistical laws that describe electromagnetic field maxima distribution, and based on them, a novel expression that could be useful to obtain a lower limit for the number of stirrer positions required at least to obtain a specific value for the normalized dispersion used to evaluate field uniformity with the IEC calibration method, being therefore of particular interest for OTA measurements.

1. Introduction

A mode-stirred reverberation chamber (RC) is an electrically large, highly conductive enclosed cavity commonly accepted as performing tool for electromagnetic (EM) measurements (both emissions and immunity) on electronic equipment and for over-the-air (OTA) communication system evaluation. It is typically equipped with mechanical stirrers that modify its electromagnetic field boundary conditions, and when it is well stirred, that is, when a sufficient number of modes are excited, the resulting environment is essentially statistically uniform and statistically isotropic (i.e., the energy having arrived from all aspect angles and at all polarizations) with independence of location [1], achieving the field uniformity requirements, except for those observation points in close proximity to walls [2] and nearby objects. The field uniformity property of an ideal reverberation chamber is such that the mean-square value of the electric field and its rectangular components is considered independent of position [1]; likewise, the real and imaginary parts of each rectangular component of the electric and magnetic field throughout the chamber are Gaussian distributed, independent with identical variances; thus, the electric or magnetic field inside an ideal RC follows a single-cluster Rayleigh probability density function in amplitude and uniform distribution of phase, whereas the power fits an exponential one [3], which resembles the multipath fading in indoor scenarios of wireless communications systems. This RC behavior concerns high frequencies and can be qualified of “asymptotic” or “overmoded.” On another hand, the “undermoded” case corresponds to the lower part of the spectrum that is close to the lowest usable frequency (LUF) [4, 5]. Standard guidelines for RC operation usually involve estimating the LUF from the field uniformity of a given working volume. Field uniformity also permits to assess the behavior goodness of the RC, and its definition is based on the calibration procedure [4, 5]. The field is determined at eight points located at the working volume corners, as depicted in Figure 1, and normalized (to the square root of the input power). For each of the 8 × 3 normalized rectangular components, 𝐸𝑅, the maximum value among 𝑁 stirrer positions, 𝐸𝑅Max, is evaluated. From these 𝐸𝑅Max maxima values, the mean value 𝐸𝑅Max and empiric standard deviation 𝜎𝐸𝑅Max are calculated. Then, field uniformity is evaluated by calculating a normalized dispersion, 𝑆(dB), expressing the standard deviation 𝜎𝐸𝑅Max in terms of dB relative to the mean 𝐸𝑅Max, that is,𝑆(dB)=20log10𝜎1+𝐸𝑅Max𝐸𝑅Max.(1)

This is typically the figure of merit used to assess the performance of the RC, since the field within it is considered to be uniform if 𝑆(dB) is within 3 dB above 400 MHz, 4 dB at 100 MHz decreasing linearly to 3 dB at 400 MHz, and within 4 dB below 100 MHz [4]. Thus, field uniformity is a requirement for an RC to become a site for electromagnetic compatibility tests, in both radiated emission and susceptibility, and to provide measure reproducibility. Once field uniformity is attained in the working volume defined inside an RC, if a specific lower value of 𝑆(dB) is desired in order to obtain more accuracy for certain measurements, a higher number 𝑁 of stirrer positions are required, and if it is determined only through trial and error, calibration costs will increase, owing to the fact that calibration according to IEC standards [4, 6] is a long process, as explained before. Thus, in this contribution, we present the statistical laws that describe electromagnetic field maxima distribution, and based on them, we develop a novel methodology which relates the normalized dispersion 𝑆(dB) and the number 𝑁 of independent samples among the ones given by 𝑁 stirrer positions (whose relationship is estimated in [7]) when uniformity of the field amplitude distribution of the 3 rectangular components at the 8 points of the working volume defined inside an RC is accomplished. This methodology does not replace the IEC calibration method [4, 6], since the only way to ensure the required uniformity is to perform the corresponding 24 measurements for 𝑁 stirrer positions, and check that the collected samples are identically distributed, fitting a certain asymptotic law whose cumulative distribution function (CDF) is known. But once this is accomplished, the presented methodology can help to search for the number 𝑁 of stirrer positions necessary to obtain a desired lower 𝑆(dB) value quicker than only through trial and error, and thus decreasing calibration costs. This methodology has been validated through both simulations (by a Monte Carlo simulation, following the work presented in [5]) and measurements inside an RC. This contribution is of special interest for OTA measurements, whose standardization is underway [8], since it gives insights on the relationship between field amplitude distribution, its maxima distribution, and under the previously mentioned conditions, field uniformity inside an RC.

2. Statistical Derivation of Field Amplitude, Maxima Distribution, and Its Relationship with Field Uniformity

As in [9], where extreme value theory is used to deal with asymptotic distributions of extreme values, such as maxima, let 𝑋1,𝑋2,,𝑋𝑁 be independent and identically distributed (i.i.d.) random variables with a parent distribution function 𝐹(𝑥) and maxima 𝑌𝑁=max1𝑖𝑁{𝑋𝑖}. If there exist constants 𝑎𝑁,𝑏𝑁>0, and some nondegenerate distribution function 𝐺 such that the distribution of (𝑌𝑁𝑎𝑁)/𝑏𝑁 converges to 𝐺, then 𝐺 belongs to one of the three standard extreme value distributions: Frechet, Webull, and Gumbel distributions. The following lemma indicates a sufficient condition for a parent distribution function 𝐹(𝑥) belonging to the domain of attraction of the Gumbel distribution.

Lemma 1. Let 𝑋1,𝑋2,,𝑋𝑁 be i.i.d. random variables with a parent distribution function 𝐹(𝑥). Define 𝜔(𝐹)=sup{𝑥𝐹(𝑥)<1}. Assume that there is a real number 𝑥1 such that, for all 𝑥1𝑥<𝜔(𝐹),𝑓(𝑥)=𝐹(𝑥) and 𝐹(𝑥) exist and 𝑓(𝑥)0. If lim𝑥𝜔(𝐹)𝑑𝑑𝑥1𝐹(𝑥)𝑓(𝑥)=0,(2) then there exist constants 𝑎𝑁 and 𝑏𝑁>0 such that (𝑌𝑁𝑎𝑁)/𝑏𝑁 uniformly converges in distribution to a normalized Gumbel random variable as 𝑁. The normalizing constants 𝑎𝑁 and 𝑏𝑁 are determined by 𝑎𝑁=𝐹111𝑁,𝑏𝑁=𝐹111𝑁𝑒𝐹111𝑁,(3) where 𝐹1(𝑥)=inf{𝑦𝐹(𝑦)𝑥} [911]. Therefore, if the amplitude of an electric field rectangular component inside the RC working volume, 𝐸𝑅, follows a parent distribution function 𝐹(𝑥), then the maxima values among 𝑁 independent samples obtained through the stirring process, 𝐸𝑅Max, will follow a Gumbel distribution, whose probability density function (PDF) is 𝑔𝑦;𝑎𝑁,𝑏𝑁=1𝑏𝑁exp𝑦𝑎𝑁𝑏𝑁expexp𝑦𝑎𝑁𝑏𝑁(4) [12], where its location and scale parameters, 𝑎𝑁 and 𝑏𝑁, respectively, can be straightforwardly derived from (3). For example, if the amplitude of an electric field rectangular component inside an RC is Rayleigh distributed, that is, 𝐸𝑅Rayleigh(𝜎), since the assumption in (2) is accomplished for 𝐹(𝑥)=Rayleigh(𝜎), the maximum value among 𝑁 stirrer positions will be asymptotically Gumbel distributed, that is, 𝐸𝑅MaxGumbel(𝑎𝑁,𝑏𝑁), with 𝑎𝑁=2𝜎2ln(𝑁) and 𝑏𝑁=2𝜎2(1+ln(𝑁)ln(𝑁)), where 𝑁 is the number of independent samples among the ones given by the 𝑁 stirrer positions (whose relationship is estimated in [7], as mentioned in the introduction). Moreover, according to IEC 61000-4-21 standard [4], if the field amplitudes are normalized to the square root of the input power, 2𝜎2 will be equal to 1, and so the expressions for 𝑎𝑁 and 𝑏𝑁 are even more simplified, that is, 𝑎𝑁=ln(𝑁) and 𝑏𝑁=1+ln(𝑁)ln(𝑁). Furthermore, after knowing that the distribution of maxima values uniformly converges to a Gumbel one, in order to calculate its moments, moment convergence has to be ensured. Even though convergence in distribution is not equivalent to moment convergence in general, following the relation between convergence in distribution and moment convergence [9, 13], convergence in distribution for the maximum of nonnegative random variables, as field amplitude inside an RC, results in moment convergence. Thus, the mean value 𝐸𝑅Max and empiric standard deviation 𝜎𝐸𝑅Max of maxima values 𝐸𝑅Max which follow a Gumbel distribution can be straightforwardly derived from their mathematical definition, using the Gumbel PDF described in (4), resulting in 𝐸𝑅Max=𝑎𝑁+𝛾𝑏𝑁,𝜎𝐸𝑅Max=𝜋6𝑏𝑁,(5) where 𝛾=0.5772 is the Euler constant [11], and 𝑎𝑁 and 𝑏𝑁 were already presented in (3).

Likewise, in the particular case of attaining field uniformity inside an RC, evaluated through the IEC calibration method [4, 6], and when the collected samples of field amplitude are identically distributed for the 3 rectangular components at the 8 points of its working volume, field uniformity could also be evaluated by the following normalized dispersion:𝑆(dB)=20log10𝜋1+61𝑎𝛾+𝑁/𝑏𝑁.(6) It is obtained by substituting 𝐸𝑅Max and 𝜎𝐸𝑅Max in (1) for the values obtained from (5). However, 𝑆(dB) is not necessarily equal to 𝑆(dB), and the previously described distribution uniformity needs to be evaluated by the IEC calibration method [4, 6] and attained in order to be comparable. The advantage that (6) provides is that once the described distribution uniformity is accomplished, in order to achieve a lower dispersion 𝑆(dB), the higher number 𝑁 of stirrer positions which would be required at least can be calculated faster using it if we consider that the ratio between 𝑁 and 𝑁 should not be increased when 𝑁 is increased if the stirring method is not altered. It is worthy to note that field uniformity evaluated by means of (6) only depends on its coefficients 𝑎𝑁 and 𝑏𝑁, which are described in (3), and thus on the distribution of the field amplitude inside the RC working volume, 𝐹(𝑥), and the number of independent samples, 𝑁, among the ones given by the 𝑁 stirrer positions. Following the previous example, if the field amplitude distribution results to be Rayleigh(𝜎) for the 3 rectangular components at the 8 points of the working volume defined inside an RC, (6) becomes𝑆(dB)=20log10𝜋1+61𝛾+1/1+(1/ln(𝑁))1,(7) which depends only on the number 𝑁 of independent collected samples. Thus, (6) and (7) can also be useful to calculate the number 𝑁 of independent samples among the ones given by the 𝑁 stirrer positions from the 𝑆(dB) value calculated according to IEC standards [4, 6] when the previously described distribution uniformity is accomplished.

3. Validation through Monte Carlo Simulations

Following the works presented in [5, 14], we use a Monte Carlo simulation in order to validate the expression presented in (5), and also the one in (6) for the case of having the previously described distribution uniformity, by confirming that the maxima values among 𝑁 independent samples which follow a given parent distribution 𝐹(𝑥) follow a distribution that converges asymptotically to a Gumbel one, comparing the maxima mean value and standard deviation to the ones given by (5), and also comparing the field uniformity dispersion 𝑆(dB) to the 𝑆(dB) given by (6).

Thus, using a MATLAB script, 24 signals of a determined length 𝑁 (modeling the 3 rectangular components of the electric field at the 8 working volume corners along the same number of independent stirrer positions) are randomly generated following one specific distribution function, 𝐹(𝑥). Then, the maximum value of each signal is calculated, and the mean value and standard deviation of these 24 maxima are computed. The procedure is iterated 1000 times, and the averaged results are depicted in Figures 2 and 3, in solid lines. They are compared with the ones predicted by (5), in dotted lines. Different numbers 𝑁 of independent samples (or alternatively, independent stirrer positions), and a Rice distribution as parent distribution, with different 𝐾-factors (including 𝐾=0 in order to study the results for a Rayleigh distribution) have been used. As we can see, since maxima distribution only converges asymptotically to a Gumbel one (but does not fit exactly for a finite number 𝑁 of independent samples), there is a small bias from the simulated results to the predicted ones. However, this bias has also been corrected by multiplying 𝑏𝑁, obtained following (3), by a factor of 23/24=0.9583 (related to the 𝑀=24 maxima, as (𝑀1)/𝑀), and recalculating the statistics by means of (5), as shown in dashed lines.

Afterwards, field uniformity is evaluated by calculating the normalized dispersion 𝑆(dB) according to IEC standards [4, 6] from the simulated samples (using the statistics of the 24 maxima), and the obtained values are averaged over the 1000 Monte Carlo runs and depicted (in green) in Figures 46, for different 𝐾-factors. Moreover, 𝑆(dB) extrema [𝑆(dB)min𝑆(dB)max] have been also computed, as in [5] (and depicted in blue and red, resp.). These results are compared with the ones predicted by (6), 𝑆(dB) (depicted in black). Since a small bias appears for the same reason already explained for the statistics (mean value and standard deviation) case, 𝑏𝑁 is multiplied by the same correcting factor of 23/24, and the resulting 𝑆(dB) is also presented (in magenta).

As we can see, the mean value of the calculated 𝑆(dB), averaged along the 1000 runs of the Monte Carlo simulation, asymptotically converges to the 𝑆(dB) given by (6), with 𝑏𝑁 calculated following (3). Moreover, after multiplying 𝑏𝑁 by the correction factor of 23/24, the mean value of the calculated 𝑆(dB) fits 𝑆(dB). Similar results are obtained for other parent distributions, 𝐹(𝑥), as Weibull or Nakagami, and they are therefore not presented here for brevity. It is also worthy to note that field uniformity is improved when the 𝐾-factor of the Rice distribution (followed by the amplitude of the electric field rectangular components) increases. This is obvious since when the dominant direct coupling component of the field is increased, the Rice 𝐾-factor is also increased, and in this case, the coefficient of variation of amplitude of the electric field rectangular components is reduced, thus decreasing the normalized dispersion used to evaluate the field uniformity. Likewise, we can observe from the results that the absolute deviation between both extrema of 𝑆(dB) along the 1000 Monte Carlo simulations (which are performed considering distribution uniformity) is up to 1 dB (when each rectangular component is modeled by 𝑁=100 independent samples following a Rayleigh distribution), and this should be taken in consideration when an RC calibration is performed according to the IEC standards [4, 6] in order to consider the field within the RC as uniform or not, specially when the value of 𝑆(dB) resulted too close to the corresponding limit of 3 dB or 4 dB [4] (depending on the frequency, as mentioned in the introduction).

4. Validation through Measurements in Reverberation Chambers

In order to ensure the validity of (5), and also the one of (6) when the previously described distribution uniformity is accomplished, several measurements have been carried out in one of the RCs of the OSA Department at XLim Laboratory, whose inner view is shown in Figure 7.

Following the IEC calibration method [4, 6], the amplitude of the 𝑥-, 𝑦-, and 𝑧-rectangular components of the electric field has been measured using a triaxial probe located at the 8 corners of a delimited working volume, at a frequency of 2 GHz. At this frequency, the RC is considered to work under the “overmoded” regime inside its factory-delimited working volume, and this requirement is necessary in order to compare the results obtained from the measurements to the ones provided by the equations presented before. The associated empirical CDFs are shown in Figure 8, considering two different working volumes: one slightly inside the factory-delimited working volume and the factory-delimited working volume itself. As we can see, they asymptotically converge to a Rayleigh distribution (the differences will be attributed to a lack of independent samples, since the measurement counts only with 𝑁=100 stirrer positions). Then, the maxima values for each one of the normalized rectangular components are evaluated, and from these maxima, 𝐸𝑅Max, the mean value 𝐸𝑅Max and empiric standard deviation 𝜎𝐸𝑅Max are calculated and compared to the values given by (5). Finally, field uniformity is evaluated by calculating the normalized dispersion 𝑆(dB) according to IEC standards [4, 6], and the obtained value is compared to the one given (6). The results obtained from the measurements performed for the two different working volumes, following the IEC calibration method [4, 6], are shown in Table 1.

Likewise, when the amplitude of the rectangular components is considered to be Rayleigh, (5) gives 𝐸𝑅Max=2.2739 and 𝜎𝐸𝑅Max=0.2842, for 𝑁=100 independent samples. In addition, (6), or (7) since the considered distribution is a Rayleigh one, gives a value of 𝑆(dB)=1.0228, also for 𝑁=100 independent samples. As we can see, the measured values are very close to the one given by the equations presented in this contribution, since the assumption of having the same distribution for the amplitudes of all the rectangular components is accomplished for both measurements, as depicted in Figure 8. Moreover, the measured values of 𝑆(dB) resulted to be also situated between the minimum and maximum values, [𝑆(dB)min=0.5161,𝑆(dB)max=1.5841] calculated by the Monte Carlo simulation for 𝑁=100 independent samples, as previously depicted in Figure 4.

Furthermore, after performing the calibration according to the IEC standards [4, 6], and confirming that the distribution of the amplitude of the rectangular components of the electric field has resulted to be Rayleigh, if a lower 𝑆(dB) value was desired, in order to obtain a higher accuracy, the number 𝑁 of stirrer positions that would be required at least can be calculated using (7). For example, if 𝑆(dB) was desired to be lower than 0.5 dB, substituting 𝑆(dB) by 0.5 dB in (7), we obtain that the number 𝑁 of independent samples that are required at least for that purpose would be 29429, and performing a calibration according to IEC standards [4, 6] with a number 𝑁 of stirrer positions lower than this higher number 𝑁 would be useless, since increasing the number 𝑁 of stirrer positions cannot decrease the distribution uniformity and cannot also increase the ratio between 𝑁 and 𝑁 if the stirring method is not altered. This is specially important after seeing that the 𝑆(dB) value obtained for 𝑁=100 stirrer positions is around 1 dB, and that the absolute deviation from one calibration realization to another in the same conditions has resulted to be up to 1 dB, as confirmed by the Monte Carlo simulations previously depicted in Figure 4, and thus, the value of 𝑆(dB)=0.5 dB desired in this example could be obtained by chance using a lower number 𝑁 of stirrer positions but only because of a deviation, and not because the field is really as uniform as desired and as 𝑆(dB)=0.5 dB indicates. Therefore, (7), and in general, (6), becomes useful for calculating a lower limit for the number 𝑁 of stirrer positions to be selected in order to obtain a specific value for 𝑆(dB) dispersion when performing a calibration according to the IEC standards [4, 6], specially once distribution uniformity is attained in a previous calibration with a lower number 𝑁 of stirrer positions. In this way, the search for the desired value of 𝑆(dB) would be faster if compared to searching for it only through trial and error, and consequently, the associated calibration time and costs would be reduced.

5. Discussion and Conclusions

In this paper, the statistical laws that describe electromagnetic field maxima distribution as a Gumbel one with parameters given by (3) have been presented, thus permitting to calculate the statistics mean value and standard deviation of the maxima values distributed so using (5). Based on that, we present in (6) a novel expression which relates the normalized dispersion 𝑆(dB) used to evaluate field uniformity to the number 𝑁 of independent samples collected among the 𝑁 stirrer positions used to calibrate an RC according to the IEC standards [4, 6] for the special case of having distribution uniformity, that is, when the field amplitude of the 3 rectangular components measured at the 8 points of the working volume defined inside the RC follows the same distribution. This study has been successfully validated both through Monte Carlo simulations and measurements in an RC.

Moreover, as it has been shown in Figures 46, field uniformity measured through the IEC calibration method [4, 6] can vary more than 1 dB between two calibration realizations even when the amplitude of the electric field rectangular components is independent and identically distributed at the eight points located at the working volume corners. Thus, since repeating the calibration process enough times to calculate an estimation of the mean value of the normalized dispersion 𝑆(dB) is usually unaffordable due to time requirements, it is essential to know a lower limit for the number 𝑁 of stirrer positions to be selected in order to obtain a specific value for 𝑆(dB). This lower limit can be easily obtained from (6) by substituting 𝑆(dB) by the desired 𝑆(dB) value, taking into account that the more distribution uniformity we have and the more independent the samples between two consecutive stirrer positions are, the more this lower limit approaches the real number 𝑁 of stirrer positions required for this purpose.

Therefore, this contribution is of special interest for OTA measurements, whose standardization is underway [8], since it not only gives insights on the relationship between field amplitude distribution and its maxima distribution, but also it could help to accelerate the achievement of a specific value of 𝑆(dB) when performing a calibration according to IEC standards [4, 6] compared to doing it only through trial and error and consequently could help to reduce calibration time and costs.