Research Article

Snaps to Connect Coaxial and Microstrip Lines in Wearable Systems

Table 4

Observed variation in S-parameters around the mean value when one connection is repeated or multiple connections are fabricated and measured. Data for and :750 to 2500 MHz. Data for :0 to 2500 MHz. The last row indicates changes in the frequency, where either one of the return losses crosses 10 dB.

Repeated connection
(straight)
repeated connection
(bent)
fabrication

0.5 dB 0.8 dB 1.5 dB
0.6 dB 0.7 dB N/A
0.2 dB 0.3 dB 0.2 dB
 dB 80 MHz 120 MHz 200 MHz