Research Article
Experimental Study on Brush-Painted Passive RFID-Based Humidity Sensors Embedded into Plywood Structures
Table 2
Results of moisture absorption: mean change in mass and standard deviation after each testing time.
| | Time | After 100% RH Δm (%) mean | After 100% RH Δm (%) st. dev. | After 9 days Δm (%) mean | After 9 days Δm (%) st. dev. |
| Noncoated | 5 min | 20.51 | 0 | 0.39 | 0 | 1 h | 46.08 | 0 | 0.44 | 0 |
| IC-coated | 5 min | 22.66 | 0.08 | 0.46 | 0.03 | 1 h | 37.56 | 1.74 | 0.47 | 0.13 |
| All-coated | 5 min | 14.90 | 6.60 | 0.19 | 0.13 | 1 h | 31.22 | 5.92 | 0.47 | 0.05 |
|
|