Research Article
Surface Shape Detection with a Single Far-Field Intensity by Combined Amplitude and Phase Retrieval
Table 5
Accuracy performance under feed location errors on (Z) axis.
| Z-error (mm) | −10 | −5 | 0 | 5 | 10 |
| RMS of δr (mm) | 0.533 | 0.277 | 0.130 | 0.250 | 0.438 | RMS of δro (mm) | 0.054 | 0.057 | 0.054 | 0.056 | 0.062 | RMS of δre (mm) | 0.530 | 0.271 | 0.119 | 0.254 | 0.434 |
|
|