Research Article

Surface Shape Detection with a Single Far-Field Intensity by Combined Amplitude and Phase Retrieval

Table 6

Accuracy performance under feed pointing angle errors.

Angle-error (°)0.511.522.5

RMS of δr (mm)0.1290.1470.2050.3050.438
RMS of δro (mm)0.0520.0580.0690.0820.097
RMS of δre (mm)0.1180.1350.1930.2940.427