Research Article
Surface Shape Detection with a Single Far-Field Intensity by Combined Amplitude and Phase Retrieval
Table 6
Accuracy performance under feed pointing angle errors.
| Angle-error (°) | 0.5 | 1 | 1.5 | 2 | 2.5 |
| RMS of δr (mm) | 0.129 | 0.147 | 0.205 | 0.305 | 0.438 | RMS of δro (mm) | 0.052 | 0.058 | 0.069 | 0.082 | 0.097 | RMS of δre (mm) | 0.118 | 0.135 | 0.193 | 0.294 | 0.427 |
|
|