Abstract

A Weibull distribution has been proposed for the probability density function (PDF) of the magnitude of the E-field in a reverberation chamber (RC). However, the Weibull distribution has two parameters, and if the parameters are position sensitive, the use of the Weibull distribution could be very limited. We investigate the sensitivity of the estimated parameters of the Weibull distribution in this study; the measurement results show that the parameters of the Weibull distribution depend on the positions of the antenna (or device under test), but not sensitive, and the statistical behavior of the parameters can be quantified. This means that the model of the Weibull distribution has a wider usable frequency range than that of the Rayleigh distribution and the statistical variation of the parameters needs to be considered.

1. Introduction

Reverberation chambers (RCs) have been widely used in the electromagnetic compatibility (EMC) test and over-the-air (OTA) measurement [16]; the electrical field inside an RC in the working volume is statistically uniform, and this provides the foundation of the applications of the RC [2]. However, the RC has to work in the overmoded region to satisfy the statistical distribution model (Rayleigh distribution). It is well known that when the resonant modes (or incident waves) increase, the E-field distribution approaches the Rayleigh distribution [2, 3]. When the RC works in the undermoded region, the Weibull distribution is more applicable than the Rayleigh distribution [3].

The Weibull distribution has been verified at a specific antenna position [711]; the measurement results show that the Weibull distribution parameters for different polarized E-fields seem quite stable in a very wide frequency range [9], but the position sensitivity of the parameters has not been studied. If the parameters of the Weibull distribution are very sensitive to the positions in an RC, they will limit the application of the model and the behavior of the RC could be very difficult to characterize.

To investigate this problem, we measure the S-parameters in an RC at different positions and use the maximum likelihood estimate (MLE) method to obtain the parameters of the Weibull distribution. Section 2 provides the theory and the setup of the measurement, Section 3 analyzes the measurement results, and Section 4 summarizes the paper.

2. Theory and Measurement Setup

The Weibull distribution has been introduced to the RC in [3, 711], and its probability density function (PDF) iswhere is called the scale parameter and is the shape parameter. Note that when and , the Weibull distribution reduces to the normalized Rayleigh distribution:where is the random variable normalized to the mean value; when and , the Weibull distribution reduces to the normalized exponential distribution [8]:

Thus, the Weibull distribution is more general than the Rayleigh distribution (or exponential distribution). By applying the MLE method, the estimated parameters can be found as the solution of the equation system [3]:where the measured samples are and is the sample number.

The random variable in (1) can be the measured or [8]. In this paper, we use the measured which corresponds to the E-field magnitude distribution in an RC. The measurement setup is illustrated in Figure 1 [12]. Figure 1(a) shows the schematic plot of the measurement; the computer controls the rotation of the stirrer, the XY platform, and the frequency sweep of the vector network analyzer (VNA). For each position of antenna 2 (a probe antenna), S-parameters (1601 points, 10 MHz–3 GHz) of 360 stirrer positions were recorded [12]. The measurement scenario is illustrated in Figure 1(b), and the measured sample points are plotted in Figure 1(c). The dimensions of the RC are 0.8 m × 1.2 m × 1.2 m, and the lowest usable frequency is about 1 GHz [12]. Sample points at three different heights were measured: 30 cm, 62 cm, and 98 cm; this makes 3 × 36 = 108 positions of antenna 2. For each position, three polarizations were also measured. Typical measured scattering parameters are illustrated in Figure 1(d) with three polarizations. Because the radiation efficiency of transmitting and receiving antennas and the cavity transfer function are all small at low frequencies, show small values below 100 MHz. We have checked the variation of the insertion loss caused by the movement of the cable, which is lower than 0.2 dB at 3 GHz. Thus, the movement of the cable does not affect our results.

The Weibull distribution parameters for each position, and polarization can be obtained by applying the MLE method in (4), where the random variable is the measured normalized (normalize to the mean value). To increase the sample number, the frequency stirring is also used, where we use 50 nearest-frequency sample points in this paper. Since 50/1601 ≈ 3.1% is very small, we can assume that the antenna performance is nearly constant in this narrow band; thus, the antenna performance will not affect the PDF of the measured S-parameters. At each frequency, we have 50 × 360 = 18000 sample points to estimate . The normalized random variable X can be written aswhere means the average of mechanical stirring and frequency stirring.

3. Measurement Results

Since the Weibull distribution has been verified in the undermoded region [711], we do not repeat the hypothesis test for the Weibull distribution but focus on the estimated parameters . For each position and polarization of antenna 2, we can estimate as a function of frequency. The results are presented in Figure 2. 36 curves are overlaid for each height of antenna 2. It is interesting to note that although the estimated parameters show dependencies on the position/polarization, the variations are not sensitive and have very similar shapes. Not surprisingly, when the frequency increases, and , so the Weibull distribution reduces to Rayleigh distribution.

To quantify the statistical behavior of the estimated parameters, the mean values and the relative standard deviations (RSDs) for different heights and polarizations are illustrated in Figure 3. To have a better resolution, the x-axis is plotted in the logarithmic scale. Note that the mean values are relatively stable and the RSDs are also small. Figure 4 presents the mean values and the RSDs of the estimated including all the positions and polarizations; also note that the RSDs are relatively small.

4. Discussion and Conclusions

To investigate the parameter stability of the Weibull distribution, we have adopted very fine measurements. 108 positions with three polarizations have been measured with 360 stirrer positions. The measurement results show that the parameters for the Weibull distribution are quite stable in the undermoded region and the statistical variation can be experimentally quantified.

Although the Weibull distribution model is valid in a wide frequency range, we have to note that the parameters have uncertainties. In the uncertainty analysis, we have to consider the uncertainties from two sources: (1) the estimated mean value (the FU definition in [1]); (2) the uncertainties from the distribution model parameters. Note that the mean value of Weibull distribution in (1) isand we have normalized the samples to the mean value. Parameters and are actually not independent. Figure 5 shows the mean value of the estimated Weibull distribution for the measured 3 × 108 = 324 scenarios (including three polarizations for each antenna position), which also means that and are highly correlated.

We should note that although the Weibull distribution was found to be a good candidate to characterize the statistical behavior in the undermoded region, it may not be a unique one. There may exist other PDFs with more than two parameters to fit the undermoded region even better.

Data Availability

The data used to support this study are available from the corresponding author upon request.

Conflicts of Interest

The authors declare that there are no conflicts of interest regarding the publication of this paper.

Acknowledgments

This work was supported in part by the National Natural Science Foundation of China under Grant 61701224.