Endoscopy-MR Image Fusion for Image Guided Procedures

Table 1

It shows the actual number of points in each image, the number of the points detected, the number of correct points, the number of false positive points (FPP), and the number of false negative points (FNP).
(a) With intensity correction

ImageNumber of pointsDetected pointsCorrect pointsSensitivityFPPFNP

Im177 73730.948104
Im277 74740.96103
Im377 74740.96103
Im477 73730.948104
Im577 76760.98701
Im677 78771.010
Im777 77760.98711
Im877 76760.98701
Im977 76760.98701
Im1077 76760.98701
Im1177 76760.98701
Im1277 76760.98701
Im1377 77771.000
Im1477 76760.98701
Im1577 77771.000
Im1677 76760.98701
Im1777 76760.98701
Im1877 76760.98701
Im1977 76760.98701

Average0.9822

(b) Without intensity correction

ImageNumber of pointsDetected pointsCorrect pointsSensitivityFPPFNP

Im177 51510.66026
Im277 48480.62029
Im377 25240.31153
Im477 53520.67125
Im577 53530.68024
Im677 39380.49139
Im777 42420.54035
Im877 39390.50038
Im977 60600.77017
Im1077 56550.71122
Im1177 53530.68024
Im1277 52520.67025
Im1377 44440.57033
Im1477 42410.53136
Im1577 42400.51237
Im1677 41400.51137
Im1777 36350.45142
Im1877 36350.45142
Im1977 41330.42244

Average0.5653