Research Article

Environmental and Material Influences on the Stress-Corrosion Cracking of Steel in H2O–CO–CO2 Solutions

Table 5

Potential-dependent results of samples tested in 25% CO–75% CO2 at 45°C.

Potential Elongation Reduction in area
(mV)(mm)(mm)(mm)(%)(mm)(%)

−600 8.926.335.223.113.0541.85
−585 13.220.934.118.13.3430.27
−575 17.815.333.113.63.6417.19
−550 15.817.933.716.43.5621.68
−550 8.026.934.921.863.1936.4
−525 12.919.4532.3510.43.4525.6
−500 24.98.032.912.983.5720.34
−500 26.158.234.3519.53.0541.86
−475 10.9522.733.6516.23.1637.59
−450 23.810.834.620.82.947.43