Research Article

Determination of Susceptibility to Intergranular Corrosion of UNS 31803 Type Duplex Stainless Steel by Electrochemical Reactivation Method

Table 5

DLEPR Test results of 2205 type duplex stainless steel.

Temperature (°C)Time (min)Activation peak potential, (mV)Activation peak current density, (mA/cm2)Reactivation peak potential, (mV)Reactivation peak current density,
(mA/cm2)
Passivation current density, (mA/cm2)DOS

Solution annealed at 1050°C, 1 hr−212.7823.1304849−267.330.00639180.0014480.027634

Solution annealed at 1050°C, 1 hr + aged at 725°C100−178.3329.2261754−196.131.68570880.0336885.767805
316−185.2526.5737074−189.431.72314660.0375426.484404
1000−172.2242.2727750−177.3522.58256140.05261553.421053
3162−199.6854.2137581−195.7050.52146980.06240993.189389
10000−183.4755.7856777−191.1150.44255820.05767590.422059
31622−147.9469.6430296−160.3064.34634840.05939192.394528