Electrochemical impedance, Tafel, and linear polarization resistance data at 308 K.

Name of inhibitorInhibitor concentration (Ω cm2) (μF cm−2)E (%) (mV versus SCE) (mA/cm2)E (%)

1 M HCl8.568.94461540.0

Terminalia arjuna300.017.067.450.5478785.049.0
600.026.248.967.9461713.053.7
1200.075.938.888.9469220.085.7

Ficus religiosa300.028.763.970.7444407.054.0
600.037.863.077.7481301.080.4
1200.075.637.688.8464190.087.6

Bacopa monnieri240.041.953.579.9464518.066.3
300.074.244.288.6486218.085.8
600.0175.239.495.248975.095.1