Research Article

Corrosion Behaviour of Heat-Treated Aluminum-Magnesium Alloy in Chloride and EXCO Environments

Table 11

Electrochemical corrosion rate for the 1.23% Mg specimen.

(sec)NaCl solutionFeCl3EXCO solution
As-castRRAAs-castRRAAs-castRRA

0000000
12000.01150.00570.02980.02340.02340.0119
24000.0210.01050.05650.04350.04350.0222
36000.03020.01480.08160.06280.06160.0308
48000.03860.01850.10680.08050.08050.0394
60000.07500.02160.12830.09850.09650.0482
72000.05300.04010.15090.11580.11330.0554