Research Article

Prevention of Reinforcement Corrosion in Concrete by Sodium Lauryl Sulphate: Electrochemical and Gravimetric Investigations

Table 2

EIS parameters of steel reinforcement in concrete in the presence and absence of inhibitor for different periods.

Time Sample W%
(day)(Ohmsqrt(Hz)(Ωcm2)(μFcm−2)(Ωcm2)

160SAMPLE 12.7478.511011.9
SAMPLE 2 50.297.510993.187.2

320SAMPLE 13.5215788.514.7
SAMPLE 29.274594.266.578

480SAMPLE 13.2322327.324.3
SAMPLE 215.85740.9617386