Table 1

Values of parameters used in HT-PEMFC model.

ParameterValue

GDL porosity0.6
Membrane thickness (m)4 × 10−5
Anode film thickness (m)2.5 × 10−9
Cathode film thickness (m)1.48 × 10−9
Anode reference exchange current density (A/m2)1440
Cathode reference exchange current density (A/m2)0.0004
Anode catalyst surface area (m2/g)64
Cathode catalyst surface area (m2/g)32.25
Anode catalyst loading (mg/cm2)0.2
Cathode catalyst loading (mg/cm2)0.4
Transfer coefficient at anode0.5
Transfer coefficient at cathode0.5
Anode reference concentration (mol/cm3)0.0002
Cathode reference concentration (mol/cm3)0.0004
Anode activation energy (kJ/mol)16000
Cathode activation energy (kJ/mol)54066
Anode reference cell temperature (K)433.15
Cathode reference cell temperature (K)373.15
Reaction order1