Preliminary results [25].

Temperature (°C)Mass flow rate of coating solution (g·min−1)Concentration of coating solution (wt.%)Poorly coated tablets content (PCT) (%)Droplet Reynolds numberIntertablet uniformity (CV)

507.8520.916720.0116
509.9029.916470.0126
507.85514.03450.0150
509.90534.03380.0170
507.851049.71030.0170
607.8522.316720.0106
609.9023.616470.0132
607.8554.03450.0146
609.90513.13380.0166