Experimental carbon dioxide solubility in aqueous potassium salt of L-histidine.

Concentration (M)Temperature (K)
313.15333.15353.15
P (kPa)α (mol. (mol·HisK−1))P (kPa)α (mol. (mol·HisK−1))P (kPa)α (mol. (mol·HisK−1))

1.0154.001.1007392.600.8512360.300.6319
511.001.2621623.901.0293621.600.7239
1001.01.50291011.71.18991023.40.7924
1499.01.72221448.91.24191434.90.9988
2055.01.80001923.91.25332021.61.1379
2418.01.91532605.11.36012641.11.1405
2801.02.08972992.61.49683123.51.2897
3450.02.23563523.91.61113555.81.4457
3901.02.39904192.61.80894078.91.5379

2.5205.100.6782352.600.5996230.100.4279
502.600.6990523.900.6665455.100.4659
911.400.8031942.600.78651136.40.5843
1432.60.92761861.40.89911436.40.6076
1972.61.10502286.40.91151905.100.7687
2423.91.13302792.60.96722361.40.7968
2837.51.16263155.10.98032917.60.8400
3398.91.28983448.91.00003598.90.9025
3930.11.35543905.11.14643923.90.9982