Research Article

Effect of Thermocycling, Teeth, and Polymerization Methods on Bond Strength Teeth-Denture Base

Table 2

Mean values (±SD) of shear bond strength (MPa) of the artificial teeth and polymerization methods with or without thermocycling.

TeethWithout thermocyclingWith thermocycling
ConventionalMicrowaveConventionalMicrowave

Premium4.12 (1.08) A,b6.68 (1.17) A,a3.90 (0.76) A,b7.24 (1.80) A,a
Trilux2.74 (0.63) B,b5.61 (0.79) A,a1.78 (0.40) B,b4.46 (1.44) B,a
Soluut4.00 (1.12) A,b6.00 (1.13) A,a3.82 (0.77) A,b5.62 (0.47) AB,a
Biotone4.45 (1.16) A,a5.78 (0.84) A,a4.11 (1.14) A,a5.65 (132) AB,a
Pool mean4.92 (1.59)4.57 (1,89)