Research Article

Comparison of Overall Fit of Milled and Laser-Sintered CAD/CAM Crown Copings

Table 2

Overall fit discrepancies of the CNCM group.

Specimen nameMeanMinimal valueMaximal valueStandard deviationStandard error (μm)

CNCM142.3437.2147.172.9050.04
CNCM242.2736.6547.722.8710.04
CNCM342.1735.9548.133.2540.04
CNCM442.2236.6447.612.9120.04
CNCM542.3536.5648.023.1610.03
CNCM642.1236.1547.682.9270.05
CNCM742.1535.8647.652.9150.05
CNCM841.9335.7248.033.2040.03
CNCM942.1736.6847.582.8820.04
CNCM1042.2736.0148.333.3230.04
Mean total42.2036.3447.793.040.04