Mechanical properties of the materials used.

Structural elementPoisson’s ratioYoung’s modulus (MPa)Reference

Cortical bone0.313700Barbier et al. [22]
Cancellous bone0.31370Barbier et al. [22]
Ti6Al4V0.3135000Brunski et al. [23]
Grade 4 titanium0.3114000Brunski et al. [23]
Zirconia abutment0.31200000
Zirconia core0.31200000
Zirconia veneer0.26580000