Research Article

Value of Contrast-Enhanced Ultrasound in Adjusting the Classification of Chinese-TIRADS 4 Nodules

Table 1

The diagnostic efficiency of the C-TIRADS 4 before and after the adjustment based on CEUS.

NodulesTotal before the adjustmentTotal after the adjustmentGroup I before the adjustmentGroup I after the adjustmentGroup II before the adjustmentGroup II after the adjustment

n12512555557070
Sensitivity (%)83.6(56/67)91.0(61/67)84.6(22/26)84.6(22/26)82.9(34/41)95.1(39/41)
Specificity (%)63.8(37/58)82.8(48/58)62.1(18/29)75.9(22/29)65.5(19/29)89.7(26/29)
Accuracy (%)74.4(93/125)87.2(109/125)72.7(40/55)80.0(44/55)75.7(53/70)92.9(65/70)
PPV (%)72.7(56/77)85.9(61/71)66.7(22/33)75.9(22/29)77.3(34/44)92.9(39/42)
NPV (%)77.1(37/48)88.9(48/54)81.8(18/22)84.6(22/26)73.1(19/26)92.9(26/28)
AUC0.7370.8690.7330.8020.7420.924
Z3.2881.3942.931
0.0010.1630.003

C-TIRADS: the Chinese-Thyroid Imaging Report and Data System; CEUS: contrast-enhanced ultrasound; PPV: positive predictive value; NPV: negative predictive value; AUC: area under the ROC curve.