Research Article

Protection of Steel Rebar in Salt-Contaminated Cement Mortar Using Epoxy Nanocomposite Coatings

Table 1

Parameters of equivalent circuits for the uncoated and coated neat resin rebar in different chloride cement mortars (0.3 and 0.5 wt.%) after 7, 28, and 56 days in 0.1 M NaOH solution.

Time of
ponding (days)
(Ω) (kΩ) (F) (MΩ) (F) (kΩ) (F)

Uncoated, 0.3 wt.% chloride cement mortar

7108.7139.7100.0
28103.747.795.5
56128.776.399.8

Uncoated, 0.5 wt.% chloride cement mortar

7136.7200.0100.0
28113.643.443.4
56152.8100.0100.0

Coated with neat resin, 0.3 wt.% chloride cement mortar

734810.6522.63185.6
283843.0842.212.09
564024.1260.33.32

Coated with neat resin, 0.5 wt.% chloride cement mortar

7224.232.613393.8
28221.815.8818.3920.69
56256.515.7167.722.90