Instrument parameters for the initial FPIs to be used in this network.

ParameterPARIIllinoisMichiganKentucky

Etalon aperture (cm)10.010.07.07.0
Etalon reflectivity78%~80%78%78%
630.0 nm filter transmission55%TBD55%55%
(~55% expected)
no. of orders imaged10101010
Etalon gap1.5 cm1.5 cm1.5 cm1.5 cm
Andor CCD detectorDU-412DU-434iKon-934DU-434
CCD readout noise4 e/pixel3 e/pixel3 e/pixel3 e/pixel